Resetting the switch to default 

To reset the IP address to the default IP address

 

“192.168.0.100” and the user password to factory default mode 

(default password is “admin”), press the hardware reset button 

on the front panel for about 10 seconds. After the device is 

rebooted, log in to the management Web interface within the 

same subnet of 192.168.0.xx and default password. Note that 

all the previous setups are erased after the factory default 

reset.  

Figure 10: Reset button 

 

Contact information 

North America 

+1 855.286.8889  

[email protected] 

www.interlogix.com/support 

Latin America 

+1 561-998-6114 

[email protected] 

Europe, Middle East, and Africa 

Select 

Contact Us

 at www.utcfssecurityproducts.eu 

Australia 

[email protected] 

 

4 / 4 

 

P/N 1073385-EN • REV A • ISS 02MAR18 

Summary of Contents for NS3500-24T-4C

Page 1: ...CP IP protocols Workstations are installed with Ethernet NIC Network Interface Card Serial port connection Terminal The above workstations come with a COM Port DB9 or USB to RS232 converter The above workstations have been installed with a terminal emulator such as Hyper Terminal included in Windows XP 2003 Serial cable One end is attached to the RS232 serial port and the other end is attached to ...

Page 2: ... terminal NS3500 24T 4C config interface vlan 1 NS3500 24T 4C config if vlan ip address 192 168 1 100 255 255 255 0 The previous command would apply the following settings for the managed switch IP Address 192 168 1 100 Subnet Mask 255 255 255 0 Figure 5 Configuring the IP address screen 4 Repeat step 1 to check if the IP address has changed Store the current switch configuration 5 At the prompt t...

Page 3: ...eft side of the web page permits access to all the functions and status provided by the managed switch Refer to the User Manual for further information about using the web management interface Note For security purposes change and memorize the new password after this first setup Saving the configuration The running configuration file is stored in the RAM of the managed switch In the current versio...

Page 4: ...terface within the same subnet of 192 168 0 xx and default password Note that all the previous setups are erased after the factory default reset Figure 10 Reset button Contact information North America T 1 855 286 8889 E techsupport interlogix com W www interlogix com support Latin America T 1 561 998 6114 E latam interlogix com Europe Middle East and Africa W Select Contact Us at www utcfssecurit...

Reviews: