background image

 

NS2052-8P-2C Industrial 

PoE+ Switch User Manual 

P/N 1073392-EN 

• REV 

• ISS 

07FEB18 

 

Summary of Contents for NS2052-8P-2C

Page 1: ...NS2052 8P 2C Industrial PoE Switch User Manual P N 1073392 EN REV A ISS 07FEB18 ...

Page 2: ...rcial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Canada Th...

Page 3: ...ER IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY RELATED PRODUCTS For more information on warranty disclaimers and product safety information please check www firesecurityproducts com policy product warning or scan the following code Contact information and manuals For contact information go to www interlogix com or www firesecurityproducts com To get translations for t...

Page 4: ......

Page 5: ...nsions 4 Product features 9 Product specifications 10 Chapter 3 Installation 13 DIN rail mounting 13 Wall mount plate mounting 15 Installing the SFP transceiver 15 Chapter 4 Troubleshooting 18 Appendix A Networking connection 19 Appendix B Approved Interlogix SFP transceivers 22 NS2052 8P 2C Industrial PoE Switch User Manual 1 ...

Page 6: ...of its essential purpose Installation in accordance with this manual applicable codes and the instructions of the authority having jurisdiction is mandatory While every precaution has been taken during the preparation of this manual to ensure the accuracy of its contents UTCFS assumes no responsibility for errors or omissions Advisory messages Advisory messages alert you to conditions or practices...

Page 7: ...contents Open the box of the industrial PoE switch and carefully unpack it The box should contain the following items The industrial PoE switch 1 CD with user manual 1 DIN rail kit x 1 Wall mounting kit x 1 If any of these are missing or damaged contact your dealer immediately If possible retain the carton including the original packing materials for repacking the product in case there is a need t...

Page 8: ...Chapter 2 Hardware introduction Physical dimensions Dimensions W x D x H 161 x 107 x 72 mm 4 NS2052 8P 2C Industrial PoE Switch User Manual ...

Page 9: ...to port 10 TP SFP combo interfaces 10 100 1000BASE T copper RJ45 twisted pair Up to 100 meters Gigabit SFP slots port 9 to port 10 TP SFP combo interfaces 1000BASE SX LX mini GBIC slot SFP Small form Factor Pluggable transceiver module From 550 meters multi mode fiber and to 10 20 30 40 50 70 120 kilometers single mode fiber NS2052 8P 2C Industrial PoE Switch User Manual 5 ...

Page 10: ...t 30 W PoE power output over a distance of up to 250 meters overcoming the 100 m limit on Ethernet UTP cable With this brand new feature the industrial PoE switch provides an additional solution for 802 3af at PoE distance extension LED indicators The front panel LEDs indicate port link status data activity and system power picture System LED Color Function P1 Green Lit indicates that the power in...

Page 11: ...at the switch is actively sending or receiving data over that port 1000 Orange Lit indicates the port has successfully connected to the network at 1000 Mbps Off indicates that the link through that port has successfully connected to the network at 10 100 Mbps Per 1000X SFP slot shared with port 9 to port 10 LED Color Function LNK ACT Green Lit indicates the port has successfully connected to the n...

Page 12: ... the power wire Caution When performing any of the procedures like inserting the wires or tightening the wire clamp screws make sure the power is OFF to prevent from getting an electric shock 1 Insert positive negative DC power wires into contacts 1 and 2 for DC Power 1 or 5 and 6 for DC Power 2 2 Tighten the wire clamp screws to prevent the wires from loosening 8 NS2052 8P 2C Industrial PoE Switc...

Page 13: ...rial PoE switch detects the fault status of the power failure and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts Wires are inserted into the fault alarm contacts Note 1 The wire gauge for the terminal block should be in the range of 12 to 24 AWG 2 Alarm relay circuits accept uo to 30 V max 3 A currents Product features Physica...

Page 14: ...um case DIN rail and wall mount design 48 to 56 VDC redundant power with polarity reverse protect function Supports Ethernet ESD protection for 6000 VDC 40 to 75 C operating temperature Switching Hardware based 10 100 Mbps half full duplex 1000 Mbps full duplex auto negotiation and auto MDI MDI X Features Store and Forward mode with wire speed filtering and forwarding rates IEEE 802 3x flow contro...

Page 15: ... to Port 8 Standard mode 30 W PoE transmit distance of 100 m at speed of 10 100 Mbps Extend mode 30 W PoE transmit distance of 250 m at speed of 10 Mbps Enclosure IP30 aluminum case Installation DIN rail kit and wall mount kit Connector Removable 6 pin terminal block for power input Pin 1 2 for Power 1 Pin 3 4 for fault alarm Pin 5 6 for Power 2 Alarm One relay output for power failure Alarm relay...

Page 16: ...gnment 1 2 3 6 PoE Power Budget Dual power input 240 W maximum depending on power input Max Number of Class 2 PDs 8 Max Number of Class 3 PDs 8 Max Number of Class 4 PDs 8 Standards Conformance Regulation Compliance FCC Part 15 Class A CE Stability Testing IEC 60068 2 32 free fall IEC 60068 2 27 shock IEC 60068 2 6 vibration Standards Compliance IEEE 802 3 10BASE T IEEE 802 3u 100BASE TX IEEE 802 ...

Page 17: ...rial PoE switch DIN rail mounting There are two methods to install the industrial industrial PoE switch DIN rail mounting and wall mount plate mounting Please read the following topics and perform the procedures in the order presented Note Follow all the DIN rail installation steps as shown in the example To install the DIN rails on the industrial PoE switch 1 Screw the DIN rail onto the industria...

Page 18: ...tallation 3 Ensure that the DIN rail is tightly attached to the track To remove the industrial PoE switch from the track Carefully remove the DIN rail from the track 14 NS2052 8P 2C Industrial PoE Switch User Manual ...

Page 19: ... panel of the industrial PoE switch 3 Use the screwdriver to screw the wall mount plate onto the industrial PoE switch 4 Use the hook holes at the corners of the wall mount plate to hang the industrial PoE switch on the wall 5 To remove the wall mount plate reverse the steps above Installing the SFP transceiver SFP transceivers are hot pluggable and hot swappable They can be plugged in and removed...

Page 20: ...ector on the network cable to the SFP SFP transceiver 2 Connect the other end of the cable to a device with the SFP SFP transceiver installed 3 Check the LNK ACT LED of the SFP SFP slot on the front of the industrial PoE switch Ensure that the SFP SFP transceiver is operating correctly 4 Check the link mode of the SFP port if the link fails Note We recommend the use of Interlogix SFPs on the indus...

Page 21: ...ontal position 4 Pull out the module gently through the lever Note Never pull out the module without making use of the lever or the push bolts on the module Removing the module with force could damage the module and the SFP SFP module slot of the industrial PoE switch NS2052 8P 2C Industrial PoE Switch User Manual 17 ...

Page 22: ...ular Check that the attached device is not set to dedicated full duplex Some devices use a physical or software switch to change duplex modes Auto negotiation may not recognize this type of full duplex setting The industrial PoE switch doesn t connect to the network Check each port LED on the industrial PoE switch Try another port Make sure the cable is installed properly and the right type Turn o...

Page 23: ...ressly forbidden is beyond the scope of this standard 10 100Mbps 10 100BASE TX When connecting the industrial PoE switch to another Fast Ethernet switch a bridge or a hub a straight or crossover cable is necessary Each port of the industrial PoE switch supports auto MDI Media Dependent Interface MDI X Media Dependent Interface Cross detection This makes it possible to directly connect the industri...

Page 24: ...e Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown SIDE 2 Crossover Cable SIDE 1 SIDE 2 SIDE 1 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown 1 White Green 2 Green 3 White Orange 4 Blue 5 White Blue 6 Orange 7 White Brown 8 Brown SIDE 2 Ens...

Page 25: ...m Multi mode 50 125 μm or 62 5 125 μm 1000BASE LX 1300 nm Multi mode 50 125 μm or 62 5 125 μm Single mode 9 125 μm Wiring distances Standard Fiber Diameter micron Modal Bandwidth MHz km Max Distance meters 1000BASE SX MM 62 5 62 5 50 50 100 200 400 500 220 275 500 550 1000BASE LX MM 62 5 50 50 5 4 5 550 SM 9 N A 5000 NS2052 8P 2C Industrial PoE Switch User Manual 21 ...

Page 26: ...1310 nm 12 20 14 32 40 to 75 C 40 to 167 F Fast Ethernet 100Base LX S20 2SLC20 LC 2 Single Mode 20 km 12 mi 1310 nm 19 15 8 34 0 to 50 C 32 to 122 F S25 2SLC20 LC 2 Single Mode 20 km 12 mi 1310 nm 19 15 8 34 40 to 75 C 40 to 167 F Fast Ethernet 100Base BX S20 1SLC A 20 LC 1 Single Mode 20 km 12 mi 1310 1550 nm 18 14 8 32 0 to 50 C 32 to 122 F S25 1SLC B 20 LC 1 Single Mode 20 km 12 mi 1550 1310 nm...

Page 27: ...40 to 167 F Gigabit Ethernet 1000 Base BX S30 1SLC A 10 LC 1 Single Mode 10 km 6 2 mi 1310 1490 nm 11 9 3 20 0 to 50 C 32 to 122 F S30 1SLC B 10 LC 1 Single Mode 10 km 6 2 mi 1490 1310 nm 11 9 3 20 0 to 50 C 32 to 122 F S30 1SLC A 20 LC 1 Single Mode 20 km 12 mi 1310 1490 nm 15 8 2 23 0 to 50 C 32 to 122 F S30 1SLC B 20 LC 1 Single Mode 20 km 12 mi 1490 1310 nm 15 8 2 23 0 to 50 C 32 to 122 F Giga...