background image

Copyright

 

© 2013  UTC Fire & Security Americas Corporation, Inc.  
Interlogix is part of UTC Climate Controls & Security, a unit of 
United Technologies Corporation.  All rights reserved. 

Trademarks and

patents

 

The IFS MC352-1P/1S and logo are trademarks of United 
Technologies. 
Other trade names used in this document may be trademarks or 
registered trademarks of the manufacturers or vendors of the 
respective products. 

Intended use

 

Use this product only for the purpose it was designed for; refer to 
the data sheet and user documentation for details. For the latest 
product information, contact your local supplier or visit us online 
at www.interlogix.com. 

Manufacturer

 

UTC Fire & Security Americas Corporation, Inc.  
2955 Red Hill Avenue 
Costa Mesa, CA 92626-5923, USA  
EU authorized manufacturing representative: 
UTC Fire & Security B.V., Kelvinstraat 7,  
6003 DH Weert, The Netherlands 

Certification

 

 

 N4131 

FCC compliance

 

This equipment has been tested and found to comply with the 
limits for a Class A digital device, pursuant to part 15 of the FCC 
Rules. These limits are designed to provide reasonable 
protection against harmful interference when the equipment is 
operated in a commercial environment. This equipment 
generates, uses, and can radiate radio frequency energy and, if 
not installed and used in accordance with the instruction manual, 
may cause harmful interference to radio communications. 
You are cautioned that any changes or modifications not 
expressly approved by the party responsible for compliance 
could void the user's authority to operate the equipment. 

ACMA compliance 

Notice!

 This is a Class A product. In a domestic environment 

this product may cause radio interference in which case the user 
may be required to take adequate measures. 

Canada 

This Class A digital apparatus complies with Canadian ICES-
003. Cet appareil numérique de la classe A est conforme á la 
norme NMB-003du Canada. 

European Union

directives

 2004/108/EC 

(EMC 

Directive): 

Hereby, UTC Fire & Security 

Americas Corporation, Inc. declares that this device is in 
compliance with the essential requirements and other relevant 
provisions of Directive 2004/108/EC.

 

 

 

 2002/96/EC 

(WEEE 

directive): 

Products marked with this 

symbol cannot be disposed of as unsorted municipal waste in 
the European Union. For proper recycling, return this product to 
your local supplier upon the purchase of equivalent new 
equipment, or dispose of it at designated collection points. For 
more information see: www.recyclethis.info.

 

Contact information

 

For contact information see our Web site: www.interlogix.com. 

Contact support

 www.interlogix.com/customer 

support 

 

 
 

Summary of Contents for MC352-1P/1S

Page 1: ...IFS MC352 1P 1S User Manual P N 1072579 REV 00 005 ISS 30JAN13...

Page 2: ...generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications You are cautioned...

Page 3: ...ring the Power Inputs 6 Wiring the Fault Alarm Contact 7 Mounting Installation 8 Link Fault Pass through LFP 12 Link Loss Carry Forward LLCF 12 Link Loss Return LLR 13 Stand alone Installation 15 802...

Page 4: ......

Page 5: ...1S series Industrial 802 3at High Power over Ethernet Gigabit Media converter also supports flow control and back pressure in half duplex operation to eliminate packet loss Package Contents Check the...

Page 6: ...oyment range the MC352 1P 1S is designed with a fiber interface The MC352 1P 1S is used to convert an optical Ethernet signal to an electrical Ethernet signal that allows two type segments to connect...

Page 7: ...igh Power over Ethernet Gigabit Media converter with maximum power output of up to 30 Watts over Ethernet cables It is designed specifically to meet the power requirements of network equipment such as...

Page 8: ...4 IFS MC352 1P 1S User Manual Hardware Overview Figure 1 All Panel Views...

Page 9: ...1P 1S User Manual 5 Front Panel The Front Panel of the Industrial 802 3at PoE Media Converter consists of one 1000Base SX 1000Base LX mini GBIC SFP port and one Auto Sensing 10 100 1000Mbps Ethernet R...

Page 10: ...wer Inputs The 6 contact terminal block connector on the top panel of the MC352 1P 1S is used for two DC redundant power inputs Please follow the steps below to insert the power wires 1 Insert positiv...

Page 11: ...iddle of the terminal block connector as the picture shows below Inserting the wires the MC352 1P 1S will detect the fault status of the power failure and then forms an open circuit The following illu...

Page 12: ...nd make connections to it Please read the following sections and perform the procedures in the order presented Note In the installation steps below this Manual uses the IFS GE DSGH 8 as an example How...

Page 13: ...tly press down and push the bottom of the DIN Rail connector mount into the track 2 Check that the DIN Rail connector mount is tightly mounted on the track 3 Please refer to following procedures to re...

Page 14: ...and pull the bottom of the DIN Rail connector mount to remove it from the track Mounting to a Wall To install the MC352 1P 1S on the wall please follow the instructions described below 1 Loosen the sc...

Page 15: ...anual 11 2 Place the wall mount plate on the rear panel of the MC352 1P 1S 3 Assemble the wall mount plate on the MC352 1P 1S 4 Use the hook holes at the corners of the wall mount plate to mount the M...

Page 16: ...eturn detects the connection loss on the fiber line Link Loss Carry Forward LLCF MC352 1P 1S incorporates an LLCF function for troubleshooting a remote connection When the LFP function is enabled the...

Page 17: ...t s transmitter shuts down when its receiver fails to detect a valid connection LLR should only be enabled on one end of the link and is typically enabled on either the unmanaged or remote device The...

Page 18: ...Note The factory default setting for the LFP function is off This feature can also be turned on via the side DIP switch If the installer is familiar with the network installation and diagnostics i e...

Page 19: ...Insert in the 100Base FX or 1000Base SX LX SFP Make sure the same type of SFP modules are used on both side i e 100Base FX 2km to 100Base FX 2km 1000Base SX 220m 550m to 1000Base SX 220m 550m etc Step...

Page 20: ...le 802 3at 802 3af Installation Before your installation it is recommended to check your network environment The MC352 1P 1S requires 48VDC or 24VDC input and it injects the DC power into the pin of t...

Page 21: ...wer 2 is on FAULT Green Lit indicates that either power 1 or power 2 has no power Gigabit Fiber Interface LED Color Function Lit indicates that the Fiber Optical Port is successfully connecting to the...

Page 22: ...ndicates that the Gigabit Ethernet Port is successfully connecting to the network at 1000Mbps OFF indicates that the Gigabit Ethernet Port is successfully connecting to the network at 10 100Mbps PoE L...

Page 23: ...Blinking Indicate that the port is actively sending or receiving data Lit Indicates a 1000Mbps Full duplex connection TP 1000 Green Off Indicates a 10 100 Mbps Full duplex connection 1000Base SX LX SF...

Page 24: ...X 1300nm Single Mode 9 125 m Fiber Distances Standard Fiber Diameter micron Modal Bandwidth MHz km Max Distance meters 1000Base SX MM 62 5 62 5 50 50 100 200 400 500 220 275 500 550 MM 62 5 50 50 5 4...

Page 25: ...ACT Green 10 100 1000Base T port LNK ACT PoE In use Green Orange LFP DIP Switch ON OFF Flow Control Back pressure for half duplex IEEE 802 3x Pause Frame for full duplex Maximum Frame Size 9216 bytes...

Page 26: ...s 16BTU Without PoE 24V 33 Watts 112BTU 48V 31 Watts 105BTU With PoE Power over Ethernet PoE Standard IEEE 802 3af 802 3at High Power over Ethernet PSE PoE Power Supply Type End Span PoE Power Output...

Page 27: ...D BI_DC 8 BI_DD BI_DC 10 100Mbps 10 100Base TX RJ 45 Connector pin assignment Contact MDI Media Dependant Interface MDI X Media Dependant Interface Cross 1 Tx transmit Rx receive 2 Tx transmit Rx rece...

Page 28: ...24 IFS MC352 1P 1S User Manual Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network...

Page 29: ...Please make sure you have the requested diagnostic or log files ready before you contact us by phone or go to www interlogix com customer support Technical Support Europe Middle East and Africa W Sel...

Reviews: