Lighting Conditions

- How good is the artificial and natural light? Will daytime and 

nighttime lighting conditions ensure adequate image quality?  
 

  If possible, locate sensor within 100 ft of the panel especially if there are many walls 

between the sensor & panel, or if the panel and sensor are located on different floors.  
While the transmitter may have an open air range of 400 ft, installation site conditions 
can reduce range considerably.  

 

  Avoid facing the sensor toward or close to areas that may affect communication such 

as metallic objects or electronics likely to produce interference. Verify sensor RF 

 

     communication at panel, even if within recommended distance.

 

 

  For optimal detection capabilities, mount the sensor where someone will most likely 

walk across the sensor coverage area as opposed to directly towards the sensor. 

 

  By default, the Image Sensor is set to “Normal” sensitivity. A more sensitive motion 

profile (“High”) and a less sensitive profile providing pet immunity for pets up to 40 lbs 
(“Low”) can be selected at the control panel or through the Alarm.com Dealer Website. 

 

  The Image Sensor is designed for indoor use only and should not be installed outdoors.  

For proper operation in pet immune applications, the room should be kept between 60° 
and 110° F. 

 

  To maximize night vision image quality, do not orient sensor towards surfaces that will 

create glare when infrared flash occurs. Avoid orienting the sensor such that the ceiling 
or adjacent walls are in the camera field of view. 

 

 

  The sensor must be mounted on a flat wall surface (do not set on shelf) free of 

 

     vibrations.   

 

 
SENSOR RESET BUTTON 

 

Insert a paperclip into the hole on the front of the sensor to access the reset button. Press 
and hold for 3 seconds to power cycle the sensor. Press and hold a full 10 seconds until 
the sensor LED flashes rapidly to reset the sensor and clear it from its network. The 
sensor must be reset prior to enrolling in a new network.  

(Note: The sensor can only be cleared from its network using the reset button if it is 
currently not communicating with its network. If the sensor is still communicating with its 
network, clear sensor by deleting it from the system it is enrolled in.) 

                        

 

                                 Figure 3.Sensor Reset Button 

BATTERY REPLACEMENT

 

When a sensor‘s batteries are low, the panel will display a low battery alert for the sensor 
(unless this trouble condition has been disabled for the panel display). Notifications are 
also issued via the Alarm.com platform if the customer has subscribed to this notification 
type.  

(Note: Low battery messages are only active at the panel between 7:00am and 10:00pm.) 
 

To replace the sensor batteries, slide the front of the sensor up off the sensor-back. (No 
need to remove or un-mount entire sensor-back and mounting arm.) To maximize battery 
life, replace the sensor batteries with 2 AA 1.5v Energizer Ultimate Lithium batteries. 
Dispose of used batteries according to the battery manufacturer instructions and following 
local regulations. 

 

Figure 4.  Removing Sensor for Battery Replacement 

 

(Note: The operation of the sensor with alkaline batteries has not been verified for  
compliance with UL standards.)

 

                                

TECHNICAL SPECIFICATIONS

 

 
Alarm.com Model Number

ADC-IS-200-LP 

 

Interlogix Part Numbers

 Image Sensor: 600-9400-IMAG 

Image Sensor Kit (Image Sensor w/ daughterboard): 600-9400-IMAG-KIT 
 

Power Source

:

 2 AA 1.5v Energizer Ultimate Lithium Batteries 

 

Expected Battery Life

:

 Approximately 2 years. Battery life varies by use case depending 

on certain factors such as weak signal strength and frequency of motion activations, image 
captures, and IR flashes. 
 

Voltage Thresholds

:

 Low battery alerts are issued at 3.05V. The sensor cannot operate 

when the voltage reads below 1.95V. 
 

Operating Temperature Range

:  

32° to 110°F for non-pet applications, 60° to 110°F for 

pet applications

 

 
Weight

:

 3.1 oz. (with batteries, without mounting accessories) 

 

Dimensions

3.1’’ h x 1.8’’ w  x 2.3’’ d 

 
Supervisory Interval

100 minutes (sensor), 3 hours (alarm hardwire)

 

 

Wireless Signal Range

:

 Greater than 400 ft open air 

 

Color

:

 White

 

 

Recommended Mounting Height

8 ft  

 

Recommended Mounting Angle

:  

6° for large coverage area and rooms greater than 30 

ft (“teeth up” on mounting arm); 18° for rooms less than 30 ft (“teeth down” on mounting 
arm) 

 

Motion Profiles & Sensor Range

Normal (up to 30 ft, default), High (up to 35 ft), Low (up 

to 25 ft)  
 

REGULATORY INFORMATION 

Changes or modifications not expressly approved by Alarm.com can void the user’s 
authority to operate the equipment. 
 
This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the 
user is encouraged to try to correct the interference by one or more of the following 
measures: 
• Re-orient or relocate the receiving antenna. 
• Increase the separation between the equipment and receiver. 
• Connect the equipment to an outlet on a circuit different from that which the receiver is 
connected 
• Consult the dealer or an experienced radio/TV technician for help. 
 
This equipment complies with the FCC RF radiation exposure limits set forth for an 
uncontrolled environment. This equipment should be installed and operated with a 
minimum distance of 20 centimeters between the radiator and your body. 
Under Industry Canada regulations, this radio transmitter may only operate using an 
antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry 
Canada. 
 
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut 
fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour 
l'émetteur par Industrie Canada.  
 
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is 
subject to the following two conditions: (1) this device may not cause interference, and (2) 
this device must accept any interference, including interference that may cause undesired 
operation of the device. 
 
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils 
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) 
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter 
tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en 
compromettre le fonctionnement. 
 
FCC ID: YL6-143IS20    IC: 9111A-143IS20 
 
 

 

Hold Here 

Slide Up 

 

Insert Paperclip to access reset button 