5. Cable Connection Parameters
The wiring details are as below:
■
100FX Fiber Optical Cables:
Standard
Fiber Type
Cable Specification
100Base-FX
(1300nm)
Multi-mode 50/125
μ
m or 62.5/125
μ
m
Multi-mode 50/125
μ
m or 62.5/125
μ
m
100Base-FX
(1310nm)
Single-mode 9/125
μ
m
100Base-BX-U
(TX :1310/RX :1550)
100Base-BX-D
(TX :1550/RX :1310)
Single-mode 9/125
μ
m
1000X Fiber Optical Cables:
Standard
Fiber Type
Cable Specification
1000Base-SX
(850nm)
Multi-mode 50/125
μ
m or 62.5/125
μ
m
Multi-mode 50/125
μ
m or 62.5/125
μ
m
1000Base-LX
(1300nm)
Single-mode 9/125
μ
m
Wiring Distances:
Standard
Fiber
Diameter (micron) Modal Bandwidth (MHz *
km)
Max. Distance (meters)
1000Base-
SX
MM 62.5
62.5
50
50
100
200
400
500
220
275
500
550
MM 62.5
50
50
5
4
5
550
1000Base-
LX
SM 9
N/A
5000*
#
Notice
The Single-mode port (1000Base-LX port) of MC350-1T-2S complies with LX 5
kilometers and provides additional margin allowing for a 10/20/40/50/60 kilometer
Gigabit Ethernet link on single mode fiber.