20
P/N 1006-7201-00 • REV A • ISS 14MAR18 ©2018 United Technologies Corporation
3.
After all alarms are powered on and the RED LED is glowing on/off, push and hold the Test/Hush button
on any one alarm until two beeps are heard (approximately 4 seconds) and then release the button. This
alarm will automatically create a new wireless network.
•
A brief series of quick GREEN LED blinks will occur and then the GREEN LED will fade on/off every
second on the button-pushed alarm (network creator).
4.
Wait for the other wireless alarms to join the wireless network.
•
A brief series of quick GREEN LED blinks will occur and then the GREEN LED will fade on/off
approximately every 3 seconds.
NOTE:
At this point, you can push/release the test button once on any alarm, and the RED LED will
flash the number of enrolled alarms.
5.
Wait for the network setup to timeout (approximately 15 minutes), OR to immediately close the network,
push the Test/Hush button until two beeps are heard (approximately 4 seconds) and then release the
button. The network can be closed from any device enrolled in the network.
•
When the network has been closed, each alarm’s GREEN LED will change from glowing on/off
every second to flashing once every 60 seconds to indicate normal operation.
6
. After selecting the proper location for your alarm, attach the mounting bracket to the wall or ceiling. To
ensure aesthetic alignment of the alarm with the hallway, or wall, the “A” line on the mounting bracket
must be parallel with the hallway when ceiling mounted or horizontal when wall mounted.
• Install the alarm fully on the mounting bracket (trim plate) by rotating the alarm in a clockwise
direction.
NOTE:
The alarm will mount to the bracket in 4 positions (every 90 degrees).
7.
The alarm is now activated. After installation / activation, test your alarm as described in