4 / 10
P/N 146575999-
1 (ML) • REV B • ISS 07MAR19
If a PIR intruder alarm if detected in the Night mode and the
detector switches back to Day mode, the red LED starts
flashing to indicate an alarm in memory.
The alarm memory is reset by switching the detector to Night
mode.
DIP switch setting
SW 1: When to signal AM (anti-masking) or TF (technical
fault) output
On: Signals AM or TF only when the system is in Day mode
(default). Note that SW 5 must be in the OFF position for this
functionality to be enabled.
Off: Always signals AM or TF during Day and Night mode.
SW 2: AM sensitivity
On: Selects a higher level of AM sensitivity. AM relay reacts
within 6 seconds.
Off: Selects the standard AM sensitivity. AM relay reacts within
12 seconds (default).
SW 3: Resetting the AM/TF output
The system will only reset an AM alarm if it has ensured that
the cause of the AM alarm has been removed. If the AM
circuitry cannot return to its original reference levels, then
either the detector is still masked or possibly has been
damaged. The owner should then visually check that the
detector is still fully functional.
On: Resets the AM or TF status 40 seconds after a PIR alarm.
Off: Resets the AM or TF status after a PIR alarm when the
system is in Day and Walk Test status. The yellow LED will
blink quickly. When the system is in Night status, the yellow
LED will turn off and the system is reset (default).
SW 4: Signaling AM or TF output
On: Signals AM on both the AM and Alarm relays. Signals TF
on the AM relay only (EN 50131).
Off: Signals AM and TF on the AM relay (default).
SW 5: Setting LEDs
On:
Enables both LEDs on the detector at all times (default).
Off: Puts both LEDs under the control of the Walk Test and
Day/Night input. This activates the memory feature of the
detector.
LED indication
PIR
Red LED
Alarm relay
To reset
Start up
Closed
Automatically after 25 s
Low voltage
Open (Alarm)
Apply correct voltage
PIR intruder
alarm
Open (Alarm)
Automatically after 3 s
PIR/AM
Red
LED
Yellow
LED
Alarm
relay
AM
relay
To reset
Start up
Closed
Closed
Automatically
after 60 s
PIR/AM
Red
LED
Yellow
LED
Alarm
relay
AM
relay
To reset
Low voltage
Open
(Alarm)
Open
(Alarm)
Apply correct
voltage
PIR intruder
alarm
Open
(Alarm)
Automatically
after 3 s
Latched PIR
(Memory)
Switch to Night
mode
AM alarm
Open*
(Alarm)
Open
(Alarm)
See DIP
switch 3
After AM
reset
Switch to Night
mode
Technical
fault
Open
(Alarm)
Do a successful
walk test
* Depends on the setting of the DIP switch SW4.
Continuously on
Normal blinking (1 Hz)
Fast (4 Hz)
Specifications
EV1012-D
EV1012AM-D
Detector
PIR
PIR + AM
Signal processing
DSP
Range
12 m
Optical
9 high-density mirror curtains
Memory
No
Yes
Input power
9 to 15 VDC (12 V nominal)
Peak-to-peak ripple
2 V (at 12 V
)
Detector start-up time
25 s
60 s
Normal current consumption
4.4 mA
10 mA
Current consumption in
alarm
1.2 mA
3.8 mA
Maximum current
consumption
11 mA
24 mA
Mounting height
1.8 m to 3.0 m
Dead zones
0.9 m at minimum mounting height
Target speed range
30 cm/s to 3 m/s
20 cm/s to 3 m/s
Alarm (NC) / Tamper relay
characteristic
80 mA
30 V
, resistive
80 mA
30 V
Pry-off tamper (not evaluated
by UL/cUL)
N/A
Onboard (yes)
AM relay characteristic
—
80 mA at 30 V
max.
Alarm time
3 s
Operating temperature
−10 to +55°C
Dimensions (H x W x D)
108 × 60 × 46 mm
Relative humidity
95% max. noncondensing
Weight
120 g
128 g
IP/IK rating
IP30 IK02
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
AUTHORIZED EU REPRESENTATIVE:
UTC Fire & Security B.V.