Chapter 3: System functions
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
47
13. Fire door
If there is no fire alarm present, generate an intrusion alarm regardless of the
status of the area. Otherwise no intrusion alarm is generated.
Example: Fire doors or emergency doors.
See also “4. Fire” on page 46.
14. Aux mains fault
Monitors the auxiliary mains supply.
15. Aux batt fault
Monitors battery of the auxiliary power supply.
16. Key box
Monitors a box that holds a key to premises. It allows you to open for a short
period after setting an area (specified in key box timer, see “8.1.4.5 Key box
time” on page 236). It generates an alarm when opened outside of this period.
17. Eng. reset
This zone activation causes the engineer reset.
18. Entry/Exit 2
An alternative entry/exit zone.
Example: Back entrance.
Entry/exit 2 zone initiates alternative entry/exit timers. See “4.2.n.2 Exit time” on
page 186” and “4.2.n.3 Entry time” on page 186.
See also “2. Entry/Exit 1” on page 45 for more details.
19. Shunt
Zone activation causes shunt of all area zones that have shunting allowed. Shunt
is allowed by the option “4.1.n.6.36 Shunt” on page 181.
See also “Zone shunt” on page 53.