background image

Copyright

 

© 2011 UTC Fire & Security. All rights reserved. 

Trademarks and

patents

 

Interlogix and IFS names and logos are trademarks of 
UTC Fire & Security. 

Other trade names used in this document may be trademarks or 
registered trademarks of the manufacturers or vendors of the 
respective products. 

Manufacturer

 

UTC Fire & Security Americas Corporation, Inc. 
2955 Red Hill Avenue, Costa Mesa, CA 92626-5923, USA 

Authorized EU manufacturing representative: 
UTC Fire & Security B.V. 
Kelvinstraat 7, 6003 DH Weert, The Netherlands 

Certification

 

 

 

N4131

 

ACMA compliance

 

Notice!

 This is a Class A product. In a domestic environment this 

product may cause radio interference in which case the user may be 
required to take adequate measures. 

Canada

 

This Class A digital apparatus complies with Canadian ICES-003. 

Cet appareil numérique de la classe A est conforme à la norme 
NMB-003 du Canada. 

European Union

directives

 

2004/108/EC (EMC directive):

 

Hereby, UTC Fire & Security 

declares that this device is in compliance with the essential 
requirements and other relevant provisions of Directive 
2004/108/EC. 

 

2002/96/EC (WEEE directive):

 

Products marked with this symbol 

cannot be disposed of as unsorted municipal waste in the European 
Union. For proper recycling, return this product to your local supplier 
upon the purchase of equivalent new equipment, or dispose of it at 
designated collection points. For more information see: 
www.recyclethis.info.

 

Contact information

 

For contact information, see www.interlogix.com. 

 

Summary of Contents for AR1000

Page 1: ...11 AT1000 AT1000 R3 AT1020 AT1020 R3 AT1025 AT1025 R3 AR1000 AR1000 R3 AR1030 AR1030 R3 IFS Fiber Module Installation Operation AR2000 AR2000 R3 AR2020 AR2020 R3 AR2025 AR2025 R3 AR2010WDMA AR2010WDMA R3 AR2010WDMB AR2010WDMB R3 ...

Page 2: ... AR1000 AUDIO OUTPUT 6 5 4 Audio Output Audio Output Ground NOTE For an unbalanced connection tie pin 2 to pin 3 and utilize pins 2 and 3 for the audio input to the AT1000 Series module Utalize pins 1 and 2 for the audio output from the AR1000 Series module ...

Page 3: ...R OPTICAL OUT POWER ifs International Fiber Systems Incorporated AR1000 FM AUDIO TRANSCEIVER 12 VAC 12 VDC 3 GRD 2 12 VAC 12 VDC 1 GRD 6 AUDIO OUT 5 AUDIO OUT 4 POWER POWER OPTICAL IN POWER CARRIER Audio Output Simplex multimode fiber optic cable Audio Input Audio Input Ground Tie together Note For unbalanced audio input use the following setup GRD 3 AUDIO IN 2 AUDIO IN 1 GRD 6 AUDIO OUT 5 AUDIO O...

Page 4: ...in 2 to pin 3 and utilize pins 1 and 2 for the audio input to the AR2000 Series module Utalize pins 4 and 5 for the audio output from the AR2000 Series module 6 5 4 3 2 1 Audio Input Audio Input Ground 6 5 4 3 2 1 Audio Output Audio Output Ground AUDIO OUTPUT ...

Page 5: ...UDIO IN 1 POWER POWER OPTICAL OUT OPTICAL IN POWER CARRIER ifs International Fiber Systems Incorporated AR2000 FM AUDIO TRANSCEIVER 12 VAC 12 VDC 3 GRD 2 12 VAC 12 VDC 1 GRD 6 AUDIO OUT 5 AUDIO OUT 4 GRD 3 AUDIO IN 2 AUDIO IN 1 POWER POWER OPTICAL OUT OPTICAL IN POWER CARRIER Audio Output Audio Output Duplex multimode fiber optic cable Audio Input Audio Input Ground Tie together Note For unbalance...

Page 6: ...AR1000 AR2000 B A Carrier LED Power LED B A AT1000 A A Power LED NOTE WITHOUT PROPER FIBER CONNECTION LED s DO NOT INDICATE CORRECT OPERATIONAL STATUS OF THE UNIT ...

Page 7: ...or Audio Connector 1 2 3 4 5 6 1 2 3 AT1000 A B B A Power Connector Audio Input Connector 1 2 3 1 2 3 AR1000 A B B A Power Connector Audio Output Connector 1 2 3 4 5 6 C D Optical Out Optical In C D C C C Optical Out C Optical In ...

Page 8: ...inches from any power source or machinery 3 Securely mount unit using 4 four mounting screws not provided 4 Attach power wires to terminal block black wire to PIN 2 and black wire with white stripe to PIN 1 5 Plug power brick into approved 120v AC outlet 6 Check power LED to insure device is properly powered LED will illuminate green ...

Page 9: ...s reasonable efforts the parties will negotiate an equitable adjustment in price d The preceding paragraph sets forth the exclusive remedies for claims based on defect in or failure of products or services whether the claim is in contract indemnity warranty tort including Seller s negligence strict liability or otherwise and however instituted Upon the expiration of the warranty period all such li...

Page 10: ...blication library To access the library go to our website at the following location http www interlogix com transmission1 Sales and support contact information North America Toll free 855 286 8889 in the US including Alaska and Hawaii Puerto Rico Canada Outside the toll free area 503 885 5700 E mail techsupport interlogix com Europe Select Contact Us at www utcfssecurityproducts eu Australia secur...

Page 11: ...and remove securement screws for printed circuit board 4 If there are multiple boards to the assembly continue removing securement screws until none are left 5 Lift off printed circuit board 6 Disassembly of box version of product is complete For rack version 1 Locate and remove securement screws for printed circuit board Usually but not limited to at least 4 screws 2 If there are multiple boards ...

Page 12: ...erference in which case the user may be required to take adequate measures Canada This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada European Union directives 2004 108 EC EMC directive Hereby UTC Fire Security declares that this device is in compliance with the essential requirements and other relevant prov...