Smart Card Reader AL1191, AL-1193 Installation Instructions 

Figure 4: Local Bus connections 

 

Tamper 

The reader has a tamper feature. When the reader is 

connected to the system databus, tamper data is transmitted to 

the Alliance system with system data. You can configure a 

tamper control for both online and offline operation using an 

external open collector output (violet wire) 

Specifications 

Current consumption 
   Standby 
   Active 

 
25 mA 
80 mA maximum 

Input voltage 

9 to 14 VDC 

Operating temperature  32 to 120°F (0 to 49°C) 

Humidity 

85% noncondensing 

 

Regulatory information 

UL listings 

UL 294 Standard for Access Control System 
Units 

UL 365 Standard for Police Station Connected 
Burglar Alarm Units and Systems 

UL 609 Standard for Local Burglar Alarm Units 
and Systems 

UL1610 Standard for Central Station Burglar 
Alarm Units 

UL 1635 Standard for Digital Alarm 
Communicator System Units

 

FCC  compliance  

This device complies w ith part 15 of the FCC 
rules. Operation is subject to the follow ing 
conditions: 

1. This device may not cause harmful 
interference. 

2. This device must accept any interference 
received, including interference that may cause 
undesired operation. 

Changes or modifications not expressly approved 
by the party responsible for compliance could 
void the user’s authority to operate the 
equipment. 

This equipment has been tested and found to 
comply w ith the limits for a Class B digital device, 
pursuant to Part 15 of the FCC  Rules. These 
limits are designed to provide reasonable 
protection against harmful interference in a 
residential installation. This equipment generates, 
uses, and can radiate radio frequency energy 
and, if not installed and used in accordance w ith 
the instructions, may cause harmful interference 
to radio communication. How ever, there is no 
guarantee that interference w ill not occur in a 
particular installation. 

If this equipment does cause harmful interference 
to radio or television reception, w hich can be 
determined by turning the equipment off and on, 
the user is encouraged to try to correct the 
interference by one or more of the follow ing 
measures: 

Reorient or relocate the receiving antenna. 

Increase the separation betw een the equipment 
and receiver. 

Connect the equipment into an outlet or a circuit 
different from the one w here the receiver is 
connected. 

Consult the dealer or an experienced ratio-TV 
technician for help. 

FCC  ID: CGGATS1190-1192. 

 

Contact information 

www.utcfireandsecurity.com

 or 

www.interlogix.com

 

For customer support, see 

www.interlogix.com/customer-

support

  

© 2012  UTC Fire & Security Americas Corporation, Inc.  

Interlogix is part of UTC Climate Controls & Security, a unit of 
United Technologies Corporation.  All rights reserved.

 

 

DGP 

AL-1191/AL-1193 

Violet 

J8  to  J12 





J22 

D- 

D+ 

0V 

+12V 

BZ 

 

4K7 

Yellow 

Red 

Black 

Green 

White 

Request-to-exit 

Reviews: