background image

© 2018 United Technologies Corporation. 

P/N 1073494A

• REV 00.00 • ISS 4JUL18 

Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation.  All rights reserved. 

 

ACL800FL-CONV-W - RS485 to TCP/IP 
converter - Installation Manual  

 

 

 

 

 

 

 

 

 

 

Description / Operation 

The ACL800FL-CONV-W is highly integrated serial to ethernet 
converter that enables you to connect any UTC biometric 
reader over a local LAN network or over the Internet to your 
computer. Configuration of the IP address, dynamic DNS, 
TCP/UDP ports can be done from browser or from the ACL800 

BioManager software. The software is capable to automatically 
search IP addresses of the converters, as well as the serial 
numbers of the biometric readers. 

The device is already preset for use with the biometric readers. 

Specifications

 

 
Power Supply: 

12VDC, 100 mA 

Network interface: 

10 BaseT, Half duplex 

RS485 interface: 

38400 Bps (8 bit data, no parity, 1 stop bit) 

“Find Portals” by   

 

ACL800 BioManager 

Yes 

POE: 

No 

Security: 

Dedicated IP or/and MAC address 

DDNS support: 

Yes 

Visual 

LED 

signalization: 

TCP/UDP packets 

DHCP client: 

Yes 

Default IP address: 

192.168.1.100 

Reset IP to default: 

Yes, by tact switch 

PCB size: 

32 x 86 mm, 4 fixing holes dia. 3 mm 

Housing: 

DIN Rail  or Wall mount, plastic, size 2 unit 

Operating 
temperature: 

0 to +40°C, noncondensing 

Dimension 

90 x 37 x 33 mm 

 

Wiring  

Figure 1: Wiring instructions 

LED 

1-  TCP Packets 

2-  UDP Packets/Reset IP 

 

 

Termination resistor 

 

 

 

 

 

 

 

 

 