RF supervision 

Receiver terminal S activates whenever the receiver goes 
one or four hours without receiving a signal from a 
supervised transmitter. To monitor for RF supervision, 
connect the receiver S output to a control panel zone input. 

Panic buttons and wireless sensor 

Panic buttons 

Use zone 1 for up to 45 unsupervised panic button 
transmitters. Use zones 2 to 8 for supervised panic button 
transmitters (2 per zone). 

Wireless sensors 

Learn wireless sensors into remaining unused zones (2 per 
zone). Make sure that both sensors learned into the same 
zone have the same expected response type at the control 
panel (delay, instant, interior, 24-hour). 

Use Table 2 to record the wireless devices used for each 
zone. 

Table 2: Transmitter zone assignments 

Receiver zone 

Panel zone 

Transmitter 

Function 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 (RF jam detect) 

 

 

 

8 (Tamper detect) 

 

 

 

 

 

 

 

 

 

Receiver programming 

This section describes the following programming 
procedures: 

• 

Learning wireless transmitters 

• 

Deleting wireless transmitters 

• 

Configuring zone/trouble outputs N/O or N/C 

• 

Configuring RF supervision 

• 

Configuring keychain touchpad zone output 

Learning wireless transmitters 

To learn a transmitter into a zone, do the following: 

1.  To enter program mode, slide the DIP switch up. The 

low battery and supervisory LEDs blink back and forth. 

2.  Press and release the ADV switch until the desired zone 

LED turn on. (If you press and hold the ADV switch, you 
will advance to the next zone and cause the zone LED 
to flicker.) 

3.  Press and release the SEL switch once to select this 

zone for learning transmitters. The zone LED remains on 
and the low battery and supervisory LEDs stop flashing. 

4.  Trip the transmitters: 

• 

For sensors with tamper switches, remove the 
cover. 

• 

For sensors without tamper switches, put the sensor 
in alarm. Each time the receiver learns a sensor, the 
selected zone LED blinks once. 

• 

For keychain touchpads: 

• 

Zone 1, press the lock and unlock buttons 
together. 

• 

Zone 2, press the lock or unlock button. 

• 

Zone 3, press the lights button. 

• 

Zone 4, press the star button. 

• 

Zone 5, press the lock button. 

• 

Zone 6, press the unlock button. 

 

Each time the receiver learns a keychain touchpad 
button, all zone LEDs with learned keychain touchpads 
blink once. 

5.  To stop learning transmitters in the selected zone, slide 

the DIP switch down. 

Repeat the procedure to learn transmitters into another zone. 

Deleting wireless transmitters 

To delete all transmitters from a zone, do the following: 

1.  To enter program mode, slide the DIP switch up. 

2.  Press and release the ADV switch until the desired zone 

LED turns on. 

3.  Press and hold the SEL switch for five seconds to delete 

all transmitters from this zone. The zone LED should 
turn off. 

Summary of Contents for 60-660-43

Page 1: ...2 MHz panic button transmitters two and four button keychain touchpads with the exception of smoke detectors Control panel compatibility The receiver is compatible with control panels designed with hardwire loops where the loop negative is ground common loop ground The receiver is not directly compatible with powered loops two wire smoke detector loops and glassbreak detector loops If the loop on ...

Page 2: ...nsistors for the zone and trouble outputs see Figure 2 The outputs can be open high impedance or closed shorted to ground which can be configured to be normally closed N C or normally open N O Each output can be wired to the control panel Zone outputs There are eight zone outputs labeled 1 through 8 When a learned transmitter is activated the corresponding zone output switches to the alarm state a...

Page 3: ...Receiver failed power up test Blinks off momentarily Receiver received an RF signal whether learned or not Run mode LED indications In run mode the LEDs indicate three conditions alarm low battery and supervisory failure Alarm status conditions When the trouble LEDs are both off the zone LEDs indicate alarm information The zone LEDs turn on for zones that are open in alarm Zone LEDs remain off for...

Page 4: ... receiver do the following 1 To remove the receiver cover press down on the top center of the cover see Figure 6 and pull the cover away from the base Figure 6 Remove the cover Caution You must be free of static electricity before handling circuit boards Touch a bare metal surface or wear a grounding strap before handling circuit boards 2 Press the lower right corner of the base until the lower ri...

Page 5: ... When learned into zone 2 both of these key presses work together to provide a maintained toggle output response only one of these buttons needs to be learned for both to work Typically this output would be used for a maintained keyswitch on the control panel for arming disarming refer to your control panel documentation for this application Zone 3 lights You can only learn this keypress into zone...

Page 6: ...de the DIP switch up The low battery and supervisory LEDs blink back and forth 2 Press and release the ADV switch until the desired zone LED turn on If you press and hold the ADV switch you will advance to the next zone and cause the zone LED to flicker 3 Press and release the SEL switch once to select this zone for learning transmitters The zone LED remains on and the low battery and supervisory ...

Page 7: ...sion on a zone do the following 1 To enter program mode slide the DIP switch up 2 Press the tamper switch twice to gain access to configuring zone supervision 3 Press and release the ADV switch until the desired zone LED turns on 4 Press and release the SEL switch to change the RF supervision configuration to the desired setting 5 Repeat the procedure for each zone configuration change 6 Slide the...

Page 8: ... responses Transmitter Should cause Sensors 7 to 8 beeps and LED flashes Keypad touchpads 1 button press 2 beeps and LED flashes 2 button press 8 beeps and LED flashes To test the system using a piezo beeper do the following 1 Connect a piezo beeper between the test output T and ground GND as shown in Figure 13 Piezo status beeper connections Figure 13 Piezo status beeper connections 2 Make sure t...

Page 9: ...nformation on warranty disclaimers and product safety information please check https firesecurityproducts com policy product warning or scan the QR code Certification TUV 0123 Test report reference CEQP 60 660 43 Applied standards EN50130 4 1995 A2 2003 Safety Test report reference CEQP 60 660 43 Applied standards EN 60950 1 2001 Radio TUV 0123 Test report reference CEQP 60 660 43 Applied standard...

Page 10: ...10 10 P N 466 1452 REV E ISS 16OCT18 ...

Reviews: