Interlogix 319.5 Installation Instructions Download Page 2

Figure 3. Board components 

Tamper switch

Battery

holder

Reed A

Input

jumper

Reed B

Positive

   External

   Contact
Terminals

 

3.  Set the panel to program mode. 

4.  Proceed to the 

Learn sensors

 menu. 

5.  Set the external contact in the alarm condition (see 

External contact wiring

). 

6.  Press and release the tamper switch (

Figure 3

) on the 

sensor until the panel responds. 

7.  Select the appropriate sensor group and number. 

8.  Exit program mode. 

Input selection 

Only one door/window input can be used at any given time. For 
example, if the external contact is used, internal reed switches 
(Reed A and Reed B in 

Figure 3

) cannot be used. 

Note:

 Power down the device before positioning the input 

selection. 

See 

Figure 4

 and position the input selection jumper to select: 

 

Reed B. 

Left two pins covered (default). 

 

Reed A. 

Right two pins covered. 

 

External contact. 

Jumper removed.  

Figure 4 Input selection jumper 

Reed A

External contact

(default)

Reed B

Jumper

location

 

Verifying RF communication 

Before mounting the sensor, verify the sensor mounting 
location provides good RF panel communication. 

To verify: 

1.  Put the panel/receiver into sensor test mode. 

2.  Take the sensor to the mounting location. 

3.  Hold the magnet next to the alignment mark on the sensor 

(

Figure 5

) and then pull the magnet away from the sensor. 

Figure 5. Alignment marks 

Sensor end view

Sensor side view

Magnet 

Alignment marks

 

4.  Listen for siren beeps to determine appropriate response 

(refer to the specific panel/receiver documentation). 

5.  Exit sensor test mode. 

Mounting 

To mount the sensor: 

1.  Remove the sensor battery. 

2.  Remove the circuit board from the sensor base by pulling 

back on the plastic tab. 

3.  Mount the sensor base using the screws provided (

Figure 

6

). 

Figure 6. Mounting holes 

Mounting

hole

Mounting

hole

Wire

entry

 

4.  Replace the circuit board. 

5.  Remove the magnet from its base. 

6.  Line up the magnet alignment mark with the sensor 

alignment mark, depending on the internal reed switch 
being used (

Figure 5

). 

7.  Mount the magnet base with the #6 x 0.625 in. PPH 

screws no more than 3/8 in. (0.95 cm) away from the 
sensor base (

Figure 7

). Replace the magnet cover. 

2  

319.5 Crystal MaxLife Door/Window Sensor Installation Instructions 

Summary of Contents for 319.5

Page 1: ...to moisture or where the operating temperature range will exceed the specified range If possible mount directly to a stud If a stud is not available use plastic anchors Avoid mounting the sensor in areas with a large quantity of metal or electrical wiring Only one input can be used at any given time You must mount the magnet within 3 8 in 0 95 cm of the sensor Mount sensors with screws not double ...

Page 2: ...nsor verify the sensor mounting location provides good RF panel communication To verify 1 Put the panel receiver into sensor test mode 2 Take the sensor to the mounting location 3 Hold the magnet next to the alignment mark on the sensor Figure 5 and then pull the magnet away from the sensor Figure 5 Alignment marks Sensor end view Sensor side view Magnet Alignment marks 4 Listen for siren beeps to...

Page 3: ...anel receiver To test the sensor refer to the specific panel receiver documentation and do the following 1 Put the panel receiver into sensor test mode 2 Open the door window the sensor is protecting The sensor transmits a signal 3 Listen for siren beeps to determine the appropriate response 4 Exit sensor test mode Battery replacement Note Battery replacement should be done by trained personnel on...

Page 4: ...thium Required batteries Duracell DL 123A Energizer EL123 Sanyo CR123A Estimated battery life 5 to 10 years at 20 C 68 F depending on the number of activations per day Magnet gap 3 8 in max Supervisory interval 64 minutes End of line resistor 4 7 Kohm Typical RF output power 0 25mW EIRP Operating temperature 32 to 120 F 0 to 49 C Storage temperature 30 to 140 F 34 to 60 C Relative humidity 0 to 85...

Reviews: