7  Installation 

 

The reader (IP 65) can be installed on a flat wall or pillar, both indoors and outdoors. 

 

The mounting plate (2) is used for fastening. The holes are designed for screw fastening to flat walls and 
also to DIN appliance cases.   

Snap-in elements (3a) in the housing cover (3) lock into place when the cover is pressed onto the mounting 
plate (2) and thus, prevent the loosening of the cover. 

 

 

The mounting plate must not get twisted out of shape when it is screwed down.   

 

The countersunk screws must end up flush with the countersunk holes and not protrude. 

 

There should be a distance of at least 20 cm from other devices with RFID readers. 

 

When the device is mounted on a metal surface, the reading distance is reduced. 

Close housing: 

The housing cover (3) is first placed over the reader electronics during    initial operation. To 

close the housing, the cover is positioned over the housing and pressed down until the snap-in elements lock 
into place in the mounting plate. 

 

Reader housing with reader electronics 

Housing cover   

1a 

5 m reader cable for connection to I/O controller board 

3a 

Snap-in elements in cover 

Mounting plate 

I/O controller board with address switches 

2a 

Drilling for reader cable   

 

 

 

 

7.1  Installation of the I/O Controller Board 

The I/O controller board (4) can be installed in a distance of up to 100 m from the reader housing (1). 

  The I/O controller board must be installed in a secured area, e.g. in a DIN appliance 

case or in a housing together with the power supply. 

 

Summary of Contents for IF-800/W02

Page 1: ...l mounting Please check the completeness and condition of the shipment upon receipt 2 Function Slave terminals of series IF 800 W02 are used for 1 controlling the access of people who identify themsel...

Page 2: ...sfer problems must be examined on a case by case basis Where necessary a shielded cable must be used for the corresponding devices 5 How to Proceed During Installation The following installation proce...

Page 3: ...aid in empty conduit 100 m 4 x 2 x 0 6 mm 2 Control line for electric actuator No specifications 2 x 2 x 0 6 mm 3 Cable to door sensor handle contact or opening push button 100 m 2 x 2 x 0 6 mm 4 RS48...

Page 4: ...ID readers When the device is mounted on a metal surface the reading distance is reduced Close housing The housing cover 3 is first placed over the reader electronics during initial operation To close...

Page 5: ...gs check the BUS address section of the higher ranking device such as e g a master terminal You can do so by using a remote program e g Telnet and entering the OC command cfg Furthermore please check...

Page 6: ...r master terminal please refer to the installation and wiring instructions included in the delivery of the respective device 1 IF 800 W02 6 Example Door monitoring connection 2 I O controller board 7...

Page 7: ...Protection Protection category III Degree of protection Reader IP65 encapsulated electronics I O board IP 00 General Data Ambient temperature 25 C to 55 C Humidity Max 95 non condensing Product safety...

Reviews: