background image

                           4

.Warning

• 

Turn off the system before installing the system. Do not plug in several electric devices to the same outlet. 

This may cause heating, fire, or electric shock.

• 

Prevent power cable from being severely bent or pressed by a heavy object. This may cause fire.

• 

Do not place any liquid container on the system, such as water, coffee, or beverage. If liquid is poured 

onto the system, it can cause a system breakdown or cause fire. 

• 

Clean the dust around the system on regular basis. When cleaning the system, always use dry cloth. Do 

not use wet cloth or other organic solvents. This may damage the surface of the system and can cause 

system breakdown or electric shock. 

• 

When pulling the power cable from the plug, do so gently. Do not touch the plug with wet hands and 

avoid using the plug if the holes on the outlet are too loose. This may cause fire or electric shock. 

• 

Avoid any place with moisture, dust, or soot. This can cause fire or electric shock.

• 

Do not attempt to disassemble, repair, or modify, the system on your own. It is extremely dangerous due 

to high voltage running through the system. This may cause fire, electric shock, or serious injuries. 

• 

Check for any danger signs such as moist floor, loosened or damaged power cable, or unstable surface. If 

you encounter any problems, ask for assistance from your dealer. This may cause fire or electric shock 

• 

Install the system in a cool place without direct sunlight and always maintain room temperature. Avoid 

candle light and heat-generating devices such as heater. Keep the system away from places where many 

people pass. This may cause file.

• 

Install the system on a plain surface with sufficient air ventilation. Do not place the system on elevated 

surface. This may cause system breakdown or serious injuries. 

.Caution

• 

Do not install the system in a place with high magnetic, electric wave, or wireless devices such as radio 

or TV. 

• 

Install the system in a place with appropriate moisture and temperature level

• 

Avoid installing the system with high (over 40℃) or low (under 0℃) temperature.

• 

Prevent any substances from being inserted into the system. This may cause system breakdown.

• 

Do not place any heavy object on the system. This may cause system breakdown. 

• 

The system can be damaged from a strong impact or vibration. 

• 

Avoid throwing objects within the vicinity of the system. 

• 

Avoid direct sunIight or any heating appliances. 

• 

The outlet must be placed on the ground. 

• 

If there is strange sound or smell, unplug the power cable immediately and contact the service center. 

This may cause fire or electric shock.

• 

It is recommended to use AVR (Automatic Voltage Regulator) for stable power supply. 

• 

In order to maintain stable system performance, have your system checked regularly by the service center.

• 

The manufacturer is not held responsible for system breakdown caused by mishandling.

• 

It is recommended to coil the core-ferrite around the connector of the system to avoid 

• 

electromagnetic Interference. 

Summary of Contents for IXIT-1612DP

Page 1: ...www intercoax com Dual Thermal IP Camera IXIT 1612DP IXIT 8060DP User Manaul Rev 1 0...

Page 2: ...0 3 System Operation Live Mode 11 3 1 Access to Live Mode 11 3 2 Live Mode Menu 12 3 3 Live Video Mode 13 3 4 Live Mode Display 14 4 System Opetation Setup Mode 15 4 1 Entering Setup Mode 15 4 2 Menu...

Page 3: ...place any conductive material through the ventilation Turn off the system before installation Ensure enough space for cable connections Place the system on a solid surface with sufficient air ventilat...

Page 4: ...tem in a cool place without direct sunlight and always maintain room temperature Avoid candle light and heat generating devices such as heater Keep the system away from places where many people pass T...

Page 5: ...er LWIR Longwave infrared Thermal Reoslution IXIT 8060DP 80 H X 60 V IXIT 1612DP 160 H X 120 V IXIT 8060DP fov 51 HFOV 63 5 diagonal f 1 1 silicon doublet IXIT 1612DP fov 56 HFOV 71 diagonal f 1 1 sil...

Page 6: ...e Rate 30 fps Resized Resolution Visual Mode Only 2592X1944 2048X1536 1600X1200 All Modes 1280X720 1024X768 640X480 Visual Mode Only 2592X1944 2048X1536 1600X1200 All Modes 1920X1080 1280X720 1024X768...

Page 7: ...d to PoE or Ethernet cable DC 12V Jack Connected to Power Cable Alarm out Connected to Alarm out Device Siren alarm light and etc 2 2 Network Connectction LAN Local Area Network RJ 45 DC 12V jack Yell...

Page 8: ...l end Sh a Saa ConuolPanel AIIConuolPa RlltNns Netwonr andS tanngCentef I CN adaptefsettmgs 0 lldv cedJhanng l J Settings Home IFind a setting Network Internet Status Wi Fi l Ethernet ll_ II View your...

Page 9: ...s set to 192 168 0 100 4 Enter ID and Password Default ID admin Default PW 1111 I I e Gmai OIDIAI m Google 0 Google l E EURL __ c __l9J_ _ 19_2 _ 16 _s_ o_ 1_00 __ Windows i The server 192 168 0 155 i...

Page 10: ...ra that is connected at long distance ex Address converting Each manufacture has own way to set up For more information please refer to the instruction manual supplied to each router or contact the ma...

Page 11: ...ormation change your password after your first login Warning pop up window will continue Run Internet Explorer as administrator There might be a limit on some menus Our thermal cameras only support In...

Page 12: ...image 7 Composition Weight This option determines the degree of synthesis of visual and thermal videos on overlay mode 8 White LED Brightness LED on the front of the camera can be turned on or off an...

Page 13: ...13 3 3 Live Video Mode Visual Thermal BW Thermal Color OVERLAY I...

Page 14: ...pper on Live Screen Setup menu Temperature above set value is displayed in maximum temperature color ex The top color on the color bar white color on White Rainbow color bar 4 Dynamic Range Lower Dyna...

Page 15: ...2 The default mode is Live mode and you can access Setup mode by pressing button as shown in the image below fJ O IT ro oc P Primary v i ComposijionWeight Whtte LEOBrightness General Video Network Eve...

Page 16: ...Screen Setup Set information and functions displayed on the screen Measurement Point Setup Set the desired temperature measurement position Up to 10 measurement points are available from 0 to 9 Video...

Page 17: ...mation Time Mode Users User ID Password Confirm Password Authority Add User Change Password User ID Current Password New Password Confirm New Password Date Time OTime Information Start Time Q TimeMode...

Page 18: ...o the formula 3 T Linear Mode OFF Use RBFO values applying manufacturer s temperature formula ON Use the temperature value from the thermal sensor FLIR Lepton without applying manufacturer s temperatu...

Page 19: ...st the deviation by entering compensation temperature on the offset h h The menu must be maintained at the factory shipment value and if any other changes or modifications are needed contact the suppl...

Page 20: ...r bar applied to Overlay Mode 10 color bars are available 5 E Event Report Alarm is triggered when the maximum set temperature is detected When Event Report is ON Event Max Temperature and Relay Outpu...

Page 21: ...t point Select Disable when you don t use temperature measurement point Select Enable when you use temperature measurement point Up to 10 measurement points available Measurement Point Setup O 10 poln...

Page 22: ...re compressed per second 1 30fps The actual number of frames may be smaller depending on each network bandwidth limit setting If the generated data cannot be transmitted on the network it appears to b...

Page 23: ...um High Highest The compression bitrate varies greatly depending on the change or movement of the frame CBR Constant BitRate The video is compressed in fixed bitrate Set it to 4Mbps or higher when the...

Page 24: ...fer specification between the server and the client The default setting value is 554 and the setting is available between 1025 and 65635 RTSP port number must be different from Web port number RTSP Lo...

Page 25: ...en until en event is triggered Event Server A This menu is for those who use a specifc VMS server named SKVMS Please skip this menu when you don t use SKVMS server For more information please contact...

Page 26: ...ff and on automatically DO NOT TURN OFF THE CAMERA DURING THE UPGRADE System Information Camera information is displayed Model Name Firmware version Serial number Hardware ID MAC address Menu Language...

Page 27: ...e the camera is connected through PPPoE possibly it happens once the network status is unstable So you can try another network connection Can t connect the camera through tab browser on Internet Explo...

Page 28: ...Please visit below website for more detailed information Web http www intercoax com Tel 031 365 3133 4 E mail info intercoax com Fax 031 365 3135 Intercoax Co Ltd Y F lntercoax Co Ltd...

Reviews: