20
1..
Horizontal / Vertical Image Sync
-
The horizontal / vertical adjustment values set on the “LIVE” mode are displayed.
2..
Dynamic Range
-
Upper(ON), Lower(ON) : Display thermal image corresponding to both maximum and minimum
temperature.
-
Upper(ON), Lower(OFF) : Display thermal image corresponding to the fixed minimum temperature.
-
Upper(OFF), Lower(ON) : Display thermal image corresponding to the fixed maximum temperature.
-
Upper(OFF), Lower(OFF) : Dynamic Range is not applied. When the upper value is set to less than the
lower value, the color of the thermal image may not display normally.
3..
Select Temperature Unit :
-
Mode_T / Kelvin
-
Mode_T / Celsius
-
Mode_T / Fahrenheit
4..
Colorbar:
-
Select a color bar applied to Overlay Mode. 10 color bars are available.
5..
E. Event Report
-
Alarm is triggered when the maximum set temperature is detected.
-
When [Event Report] is “ON”, [Event Max Temperature] and [Relay Output] are activated to be
entered.
-
The triggered alarm is transmitted to a client (ef. NVR) in ONVIF motion detection protocol.
6..
F. Event Max Temperature
-
Set the temperature at which the alarm will be triggered. Alarm is triggered when a value above that
temperature is detected.
7..
Relay Output
-
Activate the external output when an alarm is triggered.
-
The alarm output settings are in accordance with [Alarm Setup] values in [Event] menu.
8..
LED On
-
Select “ON” if you want to turn on the LED on the front of the camera when temperature alarm event
occurres.
9..
OSD
-
Enable/disable OSD display on the live screen.
-
When disbled, temperature data display on the screen is not supported.