Intercoax ITS-100 Quick Start Manual Download Page 2

Installation Guide

 

Î

Do not use the Termination Mode and Bypass Mode at the same 
time. The measurements will not be accurate.

■ Termination Mode

The termination mode is used to check the cable status where the 
camera and transmitter (Tx) are connected. The measurement is 
possible when connected to an Intercoax ECP, ETP, EUP product 
while in normal operation.
1.  Connect the ITS-100 to the transmitter (Tx) using the correct 

terminal.

 

Î

Do not connect ECP, ETC and EUP terminals at the same time. 
Connect and measure one by one.

Error

Watt

Volt

Ohm

Error

Watt

Volt

Ohm

Power Supply

ITS-100

Tx / 카메라 설치 장소

ITS-100

ITS-100

ECP/EUP/ETP

Receiver

PoE Camera

PoE Camera

PoE IN

EUP

ETP

ECP

PoE OUT

PoE IN PoE OUT

PoE

Switch

PoE

Switch

Tx / Camera location

2.  Once the ITS-100 is connected and running, the measurement 

will appear.

3.  Categories

Type of 

measurement

Content

Unit LED

Power 

available at 

installation 

place

Shows the standard voltage range of the PoE product 
when operating normally. The value for the “Available 
Power Consumption” where the tester (ITS-100) 
is installed must be greater than the total power 
consumption of the transmitter (Tx) and the camera 
to avoid problems when installing the product

Watt

Voltage at 

Installation 

place

Shows the Voltage where the tester is installed
Shows the Voltage drop when the tester (ITS-100) is 
on “Load”, not the Voltage at the Rx output, nor the 
voltage at the maximum load

Volt

Cable 

Resistance

Shows the cable resistance, measures from the 
receiver (Rx) to the tester (ITS-100)

Ohm

■ Bypass Mode

It is used to check the cable connection to a PoE camera (PoE 
product). The measurement is possible when PoE equipment 
(product with PSE function such as a PoE switch for example) is 
connected to a PoE camera and operating normally. 

Do not connect products from the EUP series in this 
mode, as it may cause damages to the device.

1.  Connection 

[CASE 1]: The ITS-100 tester is connected at the end of 
the LAN cable, on the side of the PoE (PD) camera

ⓐ  Connect the long-distance LAN cable to the ITS-100 Tester’s 

PoE IN where the camera will be installed.

ⓑ Connect the PoE camera to the ITS-100 Tester’s PoE OUT.

Error

Watt

Volt

Ohm

Error

Watt

Volt

Ohm

Power Supply

ITS-100

Tx / 카메라 설치 장소

ITS-100

ITS-100

ECP/EUP/ETP

Receiver

PoE Camera

PoE Camera

PoE IN

EUP

ETP

ECP

PoE OUT

PoE IN PoE OUT

PoE

Switch

PoE

Switch

[CASE 2]: The ITS-100 tester is connected to the PoE [PSE]

ⓐ  Connect the PSE product or the output terminal of the PoE 

switch to the ITS-100 Tester’s PoE IN.

ⓑ  Connect the long-distance LAN cable to the ITS-100 Tester’s 

PoE OUT, then connect the PoE camera at the end of the cable.

Error

Watt

Volt

Ohm

Error

Watt

Volt

Ohm

Power Supply

ITS-100

Tx / 카메라 설치 장소

ITS-100

ITS-100

ECP/EUP/ETP

Receiver

PoE Camera

PoE Camera

PoE IN

EUP

ETP

ECP

PoE OUT

PoE IN PoE OUT

PoE

Switch

PoE

Switch

2.  Once the ITS-100 tester is connected, wait a few moments 

before the measurement appears.

3.  Categories

Type of 

Measurement

Content

Unit LED

Power 

consumption 

while in 

operation

CASE 1: Shows the power consumption of the 
camera (cable loss value not included).
CASE 2: Shows the cable specifications and total 
power consumption, including the camera.

Watt

Voltage at 

installation 

place

Measures the voltage where the ITS-100 tester is 
installed.

CASE 1: Shows the cable’s voltage drop when the 

PoE camera is in operation.
CASE 2: Shows the output voltage of the PSE or the 
PoE Switch.

Volt

Cable 

resistance

Measures the cable resistance from the PSE or PoE 
switch to the ITS-100 tester. If the LAN cable is 
removed from the PoE OUT while the ITS-100 tester 
is in operation, the resistance of the cable connected 
to the PoE IN will be displayed (The resistance of the 
cable connected to the PoE OUT is not measured).

Ohm

Display 

Information

If the camera LAN cable is connected to the PoE OUT, 
the display voltage drop and power consumption 
supplied to the camera is displayed. If the camera 
LAN cable is disconnected from the PoE OUT, the 
PoE Output voltage and the cable resistance up to 

the ITS-100 Tester’s PoE IN are displayed.

-

-

Remarks

 



Because of the cable voltage drop, the measurement in wattage/
voltage decreases compared to the power supplied to the cable 
by the receiver (Rx).

 



This product is not a precision measuring device. The measurements 
have a tolerance and are not guaranteed values.

 



The tester should be used during short periods of time, especially 
when using the Termination Mode. The possibility of measurement 
differences is greater if the tester is connected for a long time in 
Termination Mode, because of heat generation.

Caution

 



Make sure to follow the instructions of the user manual when 
installing and using the device.

 



Do not use the product for projects requiring guaranteed 
measurements as this is not a precision measuring device.

 



Do not use the product for long periods of time.

 



Do not touch or handle the product and cables with wet hands, 
as there are risks of electrocution.

 



Keep away from moisture and shocks.

 



This product is designed for indoor use. Do no use outdoors.

 



Do not use the product for any other purpose than that for which 
it is designed.

 



Do not disassemble or modify this device.

 



Do not put any sticker or paint on the device.

 



If the device shows signs of defects or malfunctions, contact the 
dealer where your purchased it or the service center.

Warranty

 



This device has passed the quality control and product inspection.

 



Please install and use according to the installation guide.

 



The warranty period for this product is 24 months from the date 
of purchase.

 



If this device is defective or malfunctioning, please unplug the 
power adapter immediately and contact dealer or service center.

 



Any damages or breakage from user’s abuse, accident, 

modification or natural disasters will not be covered 

manufacturer’s warranty.

Please visit below website for more detailed information.

Web: http://www.intercoax.com 

Tel: +82. 31. 365. 3133~4

E-mail: [email protected] 

Fax: +82. 31. 365. 3135

This device complies with part 15 of the fcc rules. Operation is subject to the 
following two conditions : 
(1) This device may not cause harmful interference, and
(2)  This device must accept any interference received including interference  

 that may cause undesired operation

© Intercoax Co., Ltd.

Reviews: