Programming:
It takes three simple steps to program the BA:
1. Choose the values to be programmed.
2. Program the chosen values.
3. Check the programming by listening to the verification sounds.
1. After the program/reset button is pressed for at least two seconds a beep will sound. If the
button is released Program A can be configured. If you keep on pressing the button another two
beeps will sound after one second. One second after that three beeps will sound and another
second later four beeps will sound. If you keep on pressing after that, the programming cycle will
start again from the beginning and one beep will sound.
2. At the moment the button is released, the program that just sounded can be configured. (For
example, after three beeps sounded the user released the button, Program C can be configured.) It
can be configured by pressing the button momentarily so many times until the chosen
configuration is reached. If however the button is not activated within four seconds the the BA
will continue with step three.
3. Four seconds after the program is configured the BA will give feedback by beeps to confirm the
programming. This is done the same way as when the BA is connected for the first time.
Example:
The user would like to set 14.2V as reset value. First the user should keep the button pressed until
he hears three beeps short after each other. Then he releases the button. Following that he has to
press the button momentarily four times, because 14.2V is the fourth option in table C. (see
configuration table).
Four seconds after to have done so the BA will let you hear all programmed
values. If the user wants to change the values, the programming has to be started from the
beginning.
Configuration table:
The values with an * are default configurations.