RISK OF ELECTRIC SHOCK

DO NOT OPEN 

CAutION

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

WARNING

To prevent fire or shock hazard, do not
expose the unit to rain or moisture.

*WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used near water(e.g.

near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do
not fall and liquids are not spilled into the enclosure through openings.

*CLASS 2 WIRING (Adjacent to speaker terminal): The speaker output of this apparatus can exceed 10 Watts and could be a shock injury.

Connection to speakers should be performed by a skilled person.

*Do not install this equipment in a confined space such as a book case or similar unit.
*This apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such vases, shall be placed on the apparatus.
*This apparatus shall be connected to a mains socket outlet with a protective earthing connection.
*It has heed to be easy to disconnect the device. To disconnect the device from power, separate AC input cable from inlet or unplug the AC Cord.

CAutION

*These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing

other than that contained in the operating instructions unless you are qualified to do so.

NOtE
*

This equipment has been tested and found to comply with the limits for a Class A digital device,  pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against  harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense. 

This  symbol  is  intended  to  alert  the  user  to  the
presence  of  uninsulated  “dangerous  voltage”  within
the  product’s  enclosure  that  may  be  of  sufficient
magnitude  to  constitute  a  risk  of  electric  shock  to
persons.

This  symbol  is  intended  to  alert  the  user  to  the
presence  of  important  operation  and  maintenance
(servicing)  instructions  in  the  literature  accompanying
the appliance.

Caution: To prevent electric shock do not use this (polarized) plug with

an extension cord, receptacle or other outlet unless the blades
can be fully inserted to prevent blade exposure.

Attentions: Pour  prévenir  les  chocs  électriques  ne  pas  utiliser  cette

fiche  polarisée  avec  un  prolongateur,  une  prise  de  courant
on  une  autre  sortie  de  courant,  sauf  si  les  lames  peuvent
étre  insérées  à  fond  sans  en  laisser  aucune  partie  à
découvert.

Summary of Contents for V2-5000

Page 1: ...Operation Manual Professional Power Amplifier V2 5000...

Page 2: ...nection It has heed to be easy to disconnect the device To disconnect the device from power separate AC input cable from inlet or unplug the AC Cord CAutION These servicing instructions are for use by...

Page 3: ...Description 4 Features 4 Front Panel 5 Rear Panel 7 Applications Stereo Installation 9 Parallel Installation 9 Bridge Mono Installation 10 Linked Installation 10 Connections 11 Stereo Parallel Connect...

Page 4: ...3 Connect an appropriate line level input signal to the balanced XLR connector marked inputs 4 Move the mode selector to the desired position The Stereo position is the most common 5 Connect the outpu...

Page 5: ...a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet...

Page 6: ...rack space Switch mode power supply available for high efficiency and low weight Forced air cooled front panel intake rear panel exhaust Front panel indicators for output signal clip protect and power...

Page 7: ...g normal operation when there is an output signal 5 PROTECTION CLIP INDICATOR This warns of a problem when illuminated Reduce the level of the device which supplies signal to the amplifier or reduce t...

Page 8: ...witch determines whether the AC mains power is on or off The power on status is confirmed by the illuminated power indicator Amplifiers are always the last item in a system to be turned on It is gener...

Page 9: ...gh the amplifier the channel B output The parallel mode uses the channel A input provides signal through the amplifier to both the channel A and channel B outputs No input will be supplied to channel...

Page 10: ...distortion or damage to the amplifier or loudspeakers It is recommended to leave this switch to the ON mode to reduce distortion and help to provide protection to the loudspeakers 8 HIGH PASS FILTER S...

Page 11: ...eo Installation Parallel Installation Applications PROFESSIONAL POWER AMPLIFIER V2 5000 9 PUSH PUSH INPUT A INPUT B CH A CH B CH B CHANNEL B CHANNEL A IMX 824 832 840 PUSH PUSH INPUT A INPUT B CH A CH...

Page 12: ...allation Linking is possible when in Stereo Parallel or Bridged Mono operation PUSH PUSH INPUT A INPUT B CH A CH B CH B CHANNEL B CHANNEL A IMX 824 832 840 PUSH PUSH INPUT A INPUT B CH A CH B CH B CHA...

Page 13: ...rity clearly marked on the amplifier s rear panel and combination XLR and 1 4 phone jack are all wired in parallel 1 XLR INPUTS Balanced XLR connectors are wired as described Pin 1 Shield Pin 2 Positi...

Page 14: ...Stereo Parallel Connection Bridge Mono Connection CH A CH B CH A CH B CH B CHANNEL B CHANNEL A Wiring Using Both Speaker Connectors Wiring Two Speakers to the Channel A Speaker Connector CH A CH A CH...

Page 15: ...Block Diagram Block Diagrams PROFESSIONAL POWER AMPLIFIER 13 V2 5000...

Page 16: ...0dB 1kHz 3dB Below Rated Output Power 8 Residual Noise less than 70dB Signal to Noise Ratio 106dB Rated Output Power 8 20Hz 20kHz Output Circuitry 2 Step Class H Input Impedance 12 k Balanced HPF 30Hz...

Page 17: ...PROFESSIONAL POWER AMPLIFIER 15 V2 5000 DIMENSIONS 440 482 88 369 39...

Page 18: ...ions of this product exist to reflect the variations in AC power requirements throughout the world Product supplied through local sources are compatible with local AC power requirements Options No opt...