![Inter-m PMC-6208 Operation Manual Download Page 8](http://html1.mh-extra.com/html/inter-m/pmc-6208/pmc-6208_operation-manual_2075587008.webp)
PROGRAM MANUAL CONTROLLER
6
PMC-6208
PMC-6208 link cable Specification
Standard TIA/EIA 568B standard terminated CAT5 cable is used to connect the PMC-6208 to the DIB-6000
and PX-6216.
※
NOTE: Use only DIRECT or STRAITTIA/EIA 568B CAT5 cable.
6. POWER INPUT
DC 24V power input.
DC Power Input connection
The PMC-6208 is powered by 24V DC supplied from the PD-6359 Power distributor. Please note the
polarity of the connection, be sure to connect with us connect to an UNSWITCHED terminal.
* In the event of a power loss, audio settings will be reset to default.
UTP
1
8
1
8
[ TOP VIEW ]
DIRECT
[ CABLE COLOR ORDER ]
[ FRONT VIEW ]
8.Brown
7.W/Brown
6.Green
5.W/Blue
4.Blue
3.W/Green
2.Orange
1.W/Orange