Inter-m PMC-6208 Operation Manual Download Page 4

PROGRAM MANUAL CONTROLLER

2

PMC-6208

Installation

Unpacking

Unpacking 

Although your DAC-288 is neither complicated nor difficult to operate, we recommend you take a few minutes
to  read  this  brief  manual  and  familiarize  yourself  with  the  important  information  regarding  product  features,
setup and operation.

As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely event
the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.

Installation

Environment

Never  place  this  product  in  an  environment  which  could  alter  its  performance  or  reduce  its  service  life.  Such
environments usually include high levels of heat, dust, moisture, and vibration.

IMPORTANT SAFETY INSTRUCTIONS

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Clean only with dry cloth.
7.  Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including

amplifiers) that produce heat.

9.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades

with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and

the point where they exit from the apparatus.

11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.

When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14.  Refer  all  servicing  to  qualified  service  personnel.  Servicing  is  required  when  the

apparatus  has  been  damaged  in  any  way,  such  as  power-supply  cord  or  plug  is
damaged,  liquid  has  been  spilled  or  objects  have  fallen  into  the  apparatus,  the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.

S3125A

Summary of Contents for PMC-6208

Page 1: ...Operation Manual Program Manual Controller PMC 6208 Rack mount products in the Western Hemisphere North America South America and the Caribbean do not have handles installed due to customer preference...

Page 2: ...ate AC input cable from inlet or unplug the AC Cord CAutION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servici...

Page 3: ...tallation Environment 2 Important Safety Instructions 2 Features 3 Contents and Accessories 3 Front Panel 4 Rear Panel 5 Operation 7 Applications 11 Block Diagram 12 Specifications 13 Service Procedur...

Page 4: ...or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A gr...

Page 5: ...L Configure the matrix setting of the PX 6216 Up to four input channels can be mixed to an OUTPUT channel AUDIO INPUT VOLUME SETTING AND CONTROL Sets and controls the channel input volumes of the PX 6...

Page 6: ...3 POWER LED It indicates the power On 4 MENU BUTTON Allow access to the configuration menu 5 CURSOR MOVE BUTTONS Used to move the cursor navigate and select the menu on the LCD screen 6 ENTER BUTTON U...

Page 7: ...pgrade the system firmware 4 RESET SWITCH Used to reset the PMC 6208 to factory default setting 5 DATA IN OUT PORT RJ 45 Interface to the system 6000 components such as DIB 6000 in and PX 6216 out DC...

Page 8: ...6 POWER INPUT DC 24V power input DC Power Input connection The PMC 6208 is powered by 24V DC supplied from the PD 6359 Power distributor Please note the polarity of the connection be sure to connect w...

Page 9: ...redundant fail safe operation mode The primary mode of operation will by the PC and software When both the controller server PC and PMC 6208 are installed in tandem in a 6000 PA system the PMC 6208 w...

Page 10: ...main screen press the arrow buttons to navigate and select EQ and press ENTER key Move the cursor to the desired channel CH1 8 and press ENTER key Move the cursor to desired frequency band and set th...

Page 11: ...SC button to return to the main menu NOTE When there is a power loss audio settings will reset to default 6 SETTING SCREEN CONTRAST From the main screen press the arrow buttons to navigate and select...

Page 12: ...OLLER 1 The initial configuration of the PX 6216 is be done by PC using the MS 6800 configuration software during the system initial installation 2 Update of the PX 6216 firmware to the most recent ve...

Page 13: ...1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TERM LOAD OPEN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 FIRE SENSOR SPEAKER OUTPUT AMP INPUT H E H C E...

Page 14: ...PROGRAM MANUAL CONTROLLER 12 PMC 6208 Block Diagram Block Diagram...

Page 15: ...erating Temperature 10 C 40 C Power Source DC 24V Power Consumption 10W Weight SET 4kg 8 8lb Dimensions SET 482 W x 88 H x 280 D mm 19 W x 3 5 H x 11 D in Design and specification are subject to be ch...

Page 16: ...ilable by contacting your warranty provider Variations and Options Variations and Options Variations Products supplied through legitimate sources are compatible with local AC power requirements Option...

Page 17: ...NOTE...

Page 18: ...2 PMC 6208 NOTE...

Page 19: ...3 PMC 6208...

Page 20: ...company but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With mor...