Inter-m ECS-6216MS Operation Manual Download Page 4

EMERGENCY COMBINATION SYSTEM

2

ECS-6216MS

Installation

Unpacking

Unpacking

Although  your  ECS-6216MS  is  neither  complicated  nor  difficult  to  operate,  we  recommend  you  take  a  few
minutes  to  read  this  brief  manual  and  familiarize  yourself  with  the  important  information  regarding  product
features, setup and operation.

As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely event
the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.

Installation

Environment

Never place this product in an environment which could alter its performance or reduce its service life. Such
environments usually include high levels of heat, dust, moisture, and vibration.

IMPORTANT SAFETY INSTRUCTIONS

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Clean only with dry cloth.
7.  Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including

amplifiers) that produce heat.

9.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades

with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and

the point where they exit from the apparatus.

11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.

When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14.  Refer  all  servicing  to  qualified  service  personnel.  Servicing  is  required  when  the

apparatus  has  been  damaged  in  any  way,  such  as  power-supply  cord  or  plug  is
damaged,  liquid  has  been  spilled  or  objects  have  fallen  into  the  apparatus,  the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.

S3125A

S3125A

Summary of Contents for ECS-6216MS

Page 1: ...ration Manual Emergency Combination System ECS 6216MS Rack mount products in the Western Hemisphere North America South America and the Caribbean do not have handles installed due to customer preferen...

Page 2: ...e AC Cord The socket outlet shall be installed near the equipment and shall be easily accessible CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk...

Page 3: ...Installation Environment 2 Important Safety Instructions 2 Features 3 Equipment Setup and Inspection 4 Front Panel 5 Rear Panel 6 Applications 9 Block Diagram 10 Specifications 11 Service 12 Procedur...

Page 4: ...s or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A g...

Page 5: ...UAL BROADCAST CONTROL It can control the broadcasting of the channel you want by controlling the switches on the front side CONTROL THE 3 LINE TYPE SPEAKER TRACK It consists of the channels for the co...

Page 6: ...s of set equipment are as follow 2 TERMINATION Switch LOAD OPEN Setting 1 Termination switch on the rear panel should be set Load Open to stabilize the data transfer in case of the system linked by us...

Page 7: ...ill be on the zone selected by the button which selects the individual broadcasting zone For emergency broadcast ES red light will be pm and green will be on for the common broadcast PS The zone broad...

Page 8: ...will be transmitted to number 1 2 and 3 zones in a same time 2 PD COM TERMINAL 1 It is the contact point output terminal used for controlling the operations of the power distributor If speaker zone is...

Page 9: ...Equipment products which have RS 232 communication terminal 2 Maximum communication distance is about 12 meter 3 PIN OUT Specification 7 SPEAKER OUT TERMINAL It is the terminal which connects the chan...

Page 10: ...CY COMBINATION SYSTEM 8 ECS 6216MS 10 POWER INPUT TERMINAL It is the power input terminal Caution to polarity and connect DC 24V If it is connected with PD POWER DISTRIBUTOR connect it to UNSWITCHED T...

Page 11: ...NN EXT INT AUTO ANN REMOTE MIC MIC SW EXT INT HPF ON OFF AC INPUT FUSE DC INPUT 24V BALANCED INPUT 1V 10K LINK INPUT ADJ 12dB 0dB 100V 20 8 43 8V 4 OUTPUT COM A B 70V 10 2 FRAME FLOAT GROUND LIFT INPU...

Page 12: ...S SWITCH TIMER INPUT EXT INPUT KEY INPUT AMP INPUT CH1 AMP INPUT CH2 AMP INPUT CH16 FIRE CONTACT INPUT CH1 16 RELAY CONTROL MCU EP CONTROL JACK RS232 COMM PORT1 RS232 COMM PORT2 RS485 COMM RS485 TERMI...

Page 13: ...ce File RS 232 12m Fire Sensor Dry Contact Operating Temperature 10 C 40 C 14 F 104 F Power Source DC 24V 600mA Weight Set 4 3kg 9 5lbs Dimensions Set 482 W x88 H x280 D mm 19 W x3 5 H x11 D in Specif...

Page 14: ...ranty Warranty Warranty terms and conditions vary by country and may not be the same for all products Terms and conditions of warranty for a given product may be determined first by locating the appro...

Page 15: ...EMERGENCY COMBINATION SYSTEM 13 ECS 6216MS...

Page 16: ...mpany but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With more...

Reviews: