Set it with embedded bushes or embedded bolts.  

New concrete roughcast  

Flap type inser 

Slide type inser 

Concrete iron 

Embedded bolt  
(With embedded 
 bolt in pipe) 

Gasket 

Pendant bolt 

Nut  

Pendant  
assembly  

Suspending the indoor unit 

Use tools such as pulleys to hoist the indoor unit to the 
pendant bolt.  
Use  tools  such  as  gradienter to settle   the  indoor unit 
horizontally. Lack of horizontality may cause water leak.  

Connect the duct 

The duct length is determined according to the external 
static pressure. 

Install the wire control switch 

For  installation  of  the  wire control switch, see the 
installation manual of the wire controller.   

7.2.3    Sample unit specification figure

Fig.7-4 

Fig.7-5 

Fig.7-6 

Two pipe type

Fig.7-9 

The quantities of the fans and motors are only for reference, please prevail in kind!

Electric control box  

B (Air return port) 

A

F

Condensation 
water draining port

4-10X16Hoisting hole 

Intlet 

Outlet 

Air exhaust valve 

ϊPP

ϊPP

ϊPP

ϊPP

Ceiling

7.2.2 Space requirement.        

Fig.7-7 

Fig.7-8 

Ceiling

Summary of Contents for IFCH412KF-3

Page 1: ...412 0615 intensity mx OWNER S INSTALLATION MANUAL IFCH412KF 3 3 Tons Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep...

Page 2: ...parts and specified parts for installation otherwise it will cause the set to fall water leakage electrical shock and fire The appliance must be installed 2 3m above floor The appliance shall not be i...

Page 3: ...ensation Improper drain piping may result in water leakage and property damage Install the indoor and outdoor units power supply wiring and connecting wires at least 1 meter away from televisions or r...

Page 4: ...the indoor unit against the following figure Install 10 pendant bolts 4 bolts The intervals of the pendant bolts are shown in the following figure 7 2 Installating the fan coil units Use the 10 pendan...

Page 5: ...tality may cause water leak Connect the duct The duct length is determined according to the external static pressure Install the wire control switch For installation of the wire control switch see the...

Page 6: ...s please be specific describe which kind you need Push it this way Fig 7 9 Two grooves The accessional plastic water tray 0 1 7 g i F The grooves of the accessional plastic water tray can be locked at...

Page 7: ...ergo heat insulation treatment When performing the pipes connection use the rigid PVC binder and make sure that no leak exists Same as the joint of the indoor unit Be careful not to apply force at the...

Page 8: ...idual current device RCD with the rating of above 10mA shall be incorporated in the fixed wiring according to the national rule The appliance shall be installed in accordance with national wiring regu...

Reviews: