intensity IFCH412KF-3 Owners & Installation Manual Download Page 2

Owner’s & Installation manual 

CONTENTS 

PAGE 

PRECAUTIONS.......................................................................................1 

INSTALLATION INFORMATION................................................................2 

FUNCTIONS & FEATURES ......................................................................2 

ACCESSORIES........................................................................................2  

OPERATION  RANGE................................................................................2 

PARTS    NAMES......................................................................................3 

INSTALLATION .......................................................................................3 

PIPE CONNECTION..................................................................................6 

INSTALLATION  DRAINAGE  PIPE.............................................................6 

WIRING..................................................................................................7 

  

Be  sure  to  be  in  conformity  with  the  local,  national  and 
international laws and regulations.

Read "PRECAUTIONS" carefully before installation.

The  following  precautions  include  important  safty  items. 
Observe them and never forget.

Keep this manual  in a handy place for future reference.

Before  out  from  factory,  FAN  COIL  UNIT  (AIR  UNITS)  has 
passed  Fan  Coil  Overpressure  Resistant  Test,  Statically 
and  Dynamically  Balanced  Adjustment,  Noise  Test,  Air 
(cool)  Volume  Test,  Electric  Property  Test,  Outline  Quality 
Detection. 

1. PRECAUTIONS 

The safety precautions listed here are divided into two categories. In 
either case, important safety information is listed which must be read 
carefully. 

WARNING 

After  completing  the  installation,  make  sure  that  the  unit  operates 
properly during the start-up operation. Please instruct the customer 
on how to operate the unit and keep it maintained.

Be  sure  only  trained  and  qualified  service  personnel  to 
install, repair or service the equipment. 

Improper  installation,  repair,  and  maintenance  may  result  in 
electric  shocks,  short-circuit,  leaks,  fire  or  other  damage  to 
the equipment. 

Failure to observe a warning may result in death.

Failure  to  observe  a  caution  may  result  in  injury  or 
damage to the equipment.

CAUTION 

WARNING 

Install according to this installation instructions strictly. 

 

If  installation  is  defective,  it  will  cause  water  leakage, 
electrical shock and fire. 
 

When installing the unit in a small room, take measures 
against to keep refrigerant concentration from exceeding 
allowable safety limits in the event of refrigerant leakage.

 

Contact  the  place  of  purchase  for  more  information. 
Excessive refrigerant in a closed ambient can lead to oxygen 
deficiency.

 

 

Use  the  attached  accessories  parts  and  specified  parts 
for installation. 

 

otherwise,  it  will  cause  the  set  to  fall,  water    leakage,  
electrical shock and fire. 
 

The appliance must be installed 2.3m above floor. 
 
The appliance shall not be installed in the laundry. 
 
Before obtaining access to terminals, all supply circuits 
must be disconnected. 
 
The  appliance  must  be  positioned  so  that  the  plug  is 
accessible. 
 
The enclosure of the appliance shall be marked by word, 
or by symbols, with the direction of the fluid flow. 

 

For  electrical  work,  follow  the  local  national  wiring 
standard, regulation and this installation instructions. An 
independent circuit and single outlet must be used. 

 

If  electrical  circuit  capacity  is  not  enough  or  defect  in 
electrical work, it will cause electrical shock fire. 
 

Use  the  specified  cable  and  connect  tightly  and  clamp 
the  cable  so  that  no  external  force  will  be  acted  on  the 
terminal.

  

If  connection  or  fixing  is  not  perfect,  it  will  cause  heat-up  or 
fire at the connection. 

 
Wiring routing must be properly arranged so that control 
board cover is fixed properly. 

 

If  control  board  cover  is  not  fixed  perfectly,  it  will  cause 
heat-up  at  connection  point  of  terminal,  fire  or  electrical 
shock. 
 

If the supply cord is damaged, it must be replaced by the 
manufacture  or  its  service  agent  or  a  similarly  qualified 
person in order to avoid a hazard. 
 
An  all-pole  disconnection  switch  having  a  contact 
separation  of  at  least  3mm  in  all  poles  should  be 
connected in fixed wiring. 
 
When carrying out piping connection, take care not to let 
air substances go into refrigeration cycle. 

 

Otherwise,  it  will  cause  lower  capacity,  abnormal  high 
pressure in the refrigeration cycle. 
 

Do not modify the length of the power supply cord or use 
of extension cord, and do not share the single outlet with 
other electrical appliances. 

 

Otherwise, it will cause fire or electrical shock. 
 

If the water leaks during installation, ventilate the area 
immediately. 
 
After completing the installation work, check that the 
water does not leak. 
 

The cool water in the unit is not lower than 3

ć

, hot water is 

not higher than 80

ć

. Water in the unit must clean, air quality 

must meet to the standard of PH=6.5~7.5.

   

Summary of Contents for IFCH412KF-3

Page 1: ...412 0615 intensity mx OWNER S INSTALLATION MANUAL IFCH412KF 3 3 Tons Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep...

Page 2: ...parts and specified parts for installation otherwise it will cause the set to fall water leakage electrical shock and fire The appliance must be installed 2 3m above floor The appliance shall not be i...

Page 3: ...ensation Improper drain piping may result in water leakage and property damage Install the indoor and outdoor units power supply wiring and connecting wires at least 1 meter away from televisions or r...

Page 4: ...the indoor unit against the following figure Install 10 pendant bolts 4 bolts The intervals of the pendant bolts are shown in the following figure 7 2 Installating the fan coil units Use the 10 pendan...

Page 5: ...tality may cause water leak Connect the duct The duct length is determined according to the external static pressure Install the wire control switch For installation of the wire control switch see the...

Page 6: ...s please be specific describe which kind you need Push it this way Fig 7 9 Two grooves The accessional plastic water tray 0 1 7 g i F The grooves of the accessional plastic water tray can be locked at...

Page 7: ...ergo heat insulation treatment When performing the pipes connection use the rigid PVC binder and make sure that no leak exists Same as the joint of the indoor unit Be careful not to apply force at the...

Page 8: ...idual current device RCD with the rating of above 10mA shall be incorporated in the fixed wiring according to the national rule The appliance shall be installed in accordance with national wiring regu...