background image

131 Eisenhower Lane North

Lombard, IL 60148

630.268.0010 / 1.800.251.2408

P/N 53-00920-100 Rev. B 101505

www.intellitec.com

Intellitec

INSTALLATION AND SERVICE MANUAL

Monoplex Trio

3

1) the Switch Panel Backlit will illuminate if any of the switch panel buttons are depressed. This is a short
term activation of the backlit and the illumination will remain on for approximately ten seconds.
2) the Switch Panel Backlit will illuminate when the Parking Lights are enabled and will remain illuminated
as long as the Parking Light signal is present.

The fused power source for the Sofa Control is part of the Monoplex Trio module and provides intermittent
power up to 30 Amps for operation of the sofa settings. The operation of the Sofa Control is interrupted
when the Ignition signal is present at the Monoplex Trio module, refer to page 6 of this manual.

The TV Play Timer feature provides for the operation of the TV and the Audio system during a selectable
period of time (15 minutes to 30 minutes in 5 minute increments) when the Ignition is turned off. The TV
Play Timer will begin counting down whether the TV or Audio system is turned on prior to ignition being
removed. Once the Monoplex Trio TV Play Timer expires, cycle the ignition in order to reset the TV Play
Timer. The timer setting is selected by position 5 and 6 of SW1, Dip Switch located on the Monoplex Trio
module, (see page 6 for specifics).

There are four output channels that may be configured to dim. The channels that are dimmable are output
channels 1,2,3, and 4. The configuration to make any or all of the four output channels dimmable is
outlined for the Dip Switch, SW1, in the table below:

1

ON

Output 1 J3-1

2

ON

Output 2, J3-2

3

ON

Output 3, J3-3

4

ON

Output 4, J3-4

The Dip Switch settings are read on initial power up of the Monoplex Trio module and if changes are made
to the Dip Switch settings, it recommended that power to the module be removed and restored to have the
latest changes incorporated. The initial factory default setting for each of the output channels is 100%. All
DIP switches are initially set to the OFF position for SW1.

To program the output dim setting for a selected channel, requires that you press and hold the selected
switch for a period of three seconds in order to enable the dimming sequence. If the output has been
programmed previously, it will begin at the saved output setting.

If the output is at the factory default, then the output will decrease approximately 10% every second until
the button is released. If the button is held until the last step is reached, 10% output intensity, the output
will then increase 10% per step until the it reaches the maximum output intensity of 100%.

Sofa Control

TV Play Timer

Dimmer Operation and Setup

Position

Enable Dim

Channel

Summary of Contents for 00-01070-000

Page 1: ...tellitec com Intellitec INSTALLATION AND SERVICE MANUAL Monoplex Trio 1 CAUTION The full power of the vehicle battery is available at the power input stud on the top of the unit Service should be perf...

Page 2: ...oved from the module A Dip Switch Sw1 is used to set the dimming capabilities of the four dimming channels These can be set to be dimming for lighting or non dimming for loads such as motors There is...

Page 3: ...setting is selected by position 5 and 6 of SW1 Dip Switch located on the Monoplex Trio module see page 6 for specifics There are four output channels that may be configured to dim The channels that ar...

Page 4: ...Optional There are a number of switch panels that can be used with the module These include different styles and back lighting options In addition conventional momentary switches can used in conjuncti...

Page 5: ...Lane North Lombard IL 60148 630 268 0010 1 800 251 2408 P N 53 00920 100 Rev B 101505 www intellitec com Intellitec INSTALLATION AND SERVICE MANUAL Monoplex Trio SUGGESTED MINIMUM FOOTPRINT FOR MODULE...

Page 6: ...tus Indicator J3 1 FET Output 1 15 Amp D1 J3 2 FET Output 2 15 Amp D2 J3 3 FET Output 3 15 Amp D3 J3 4 FET Output 4 15 Amp D4 J3 5 FET Output 5 15 Amp D5 J3 6 FET Output 6 15 Amp D6 Male Faston Stab 3...

Page 7: ...ule being bad See connector details on page 6 of this manual The Monoplex Trio will cease to operate when the battery voltage drops to 9 VDC This indicates the low voltage condition and all outputs wi...

Page 8: ...litec INSTALLATION AND SERVICE MANUAL Monoplex Trio TO LOADS 12 VOLTS BATTERY Optional Back Lighting MPX Communication Bus Communication Ground Momentary Switch Programming Link Part No 00 00963 XXX D...

Page 9: ...131 Eisenhower Lane North Lombard IL 60148 630 268 0010 1 800 251 2408 P N 53 00920 100 Rev B 101505 www intellitec com Intellitec INSTALLATION AND SERVICE MANUAL Monoplex Trio 9...