7

 

3.3 CCD camera keys description 

Before the operation, pls set address 1 firstly 

Operational keys 

Function   

Up

 

PTZ up

 

Down

 

PTZ down

 

Left

 

PTZ left

 

Right

 

PTZ right

 

FOCUS- 

Near Focus 

FOCUS+ 

Far Focus 

ZOOM- 

Zoom out 

ZOOM+ 

Zoom in 

4

 

Thermal imaging camera menu 

4.1 Main-menu operations 

Before operate thermal camera .please set address 2 firstly

 

Without the menu call preset 100 to activate the main menu. Enter the main menu (pic 2): 

       

 

 

 

Press key “LENS-” move the cursor

Press key “FOCUS+” or “FOCUS-” to change the value where the cursor 

is. Auto save when exit   

1

Auto: XXX         

Display the current image auto mode. Three options: 

4  5 

Pic 2 

Summary of Contents for ThermalTronix TT-MDL-A-SDA Series

Page 1: ...ThermalTronix TT MDL A SDA Series Thermal Camera Specifications User Manual...

Page 2: ...nty If the product does not operate properly in normal conditions please let us know Intellisystem Technologies will resolve the problem for free of charge The warranty period is 1 years However the f...

Page 3: ...protect it properly during usage storage and transportation where improper use such as drop and collision will cause damage to the device Make sure that the power control connection is reliable If the...

Page 4: ...ERATION GUIDE 6 3 1 Communication parameters 6 3 2 Thermal camera control key description 6 3 3 CCD camera keys description 7 4 Thermal imaging camera menu 7 Before operate thermal camera please set a...

Page 5: ...e Reduction function reduce Image background noise Image enhancing function enhance the ability to detect small object CCD camera With the state of the art digital signal processing technology full di...

Page 6: ...mera 1 AC24 Power Adapter 1 User manual 1 Packing list 1 qualification 1 2 Component names and functions 2 1 Device appearance 2 Pic 1 No Description Remark 1 Thermal Thermal camera 2 CCD Camera Inclu...

Page 7: ...3 OPERATION GUIDE 3 1 Communication parameters Thermal camera default address PELCO D baud 2400 9600 address 2 PT system default address PELCO D baud 2400 9600 address 1 Visual camera default address...

Page 8: ...OOM Zoom in 4 Thermal imaging camera menu 4 1 Main menu operations Before operate thermal camera please set address 2 firstly Without the menu call preset 100 to activate the main menu Enter the main...

Page 9: ...digital zoom 6 Level X show the range of alarm From 1 to 6 default is 4 7 Seting Activate the setting secondary menu Press key FOCUS or FOCUS show the password dialogue Press FOCUS FOCUS FOCUS FOCUS...

Page 10: ...nter refer to Pic 4 Press key LENS move the cursor press key FOCUS or FOCUS to change the value or get into the submenu where the cursor is Auto save when exit 1 COM Setup the communication parameters...

Page 11: ...1 time during the 1 minute if working time less than 0 minute Calibrate 1 time during 2 minutes if working time between 10 and 30 minutes calibrate 1 time during 5 minutes if working time more than 3...

Page 12: ...sor Press key FOCUS or FOCUS to change the value where the cursor is Refer to Pic 5 Auto save when exit 1 ID XXX Address of the IR camera 0 254 2 BauRate XXX Baud 1200 2400 4800 9600 14400 19200 38400...

Page 13: ...ate the Mode option Press key LENS move the cursor Press key FOCUS or FOCUS to change the value where the cursor is Refer to Pic 6 Auto save when exit 1 Gain XXX Range 0 255 2 Bright XXX Range 0 255 3...

Page 14: ...rmPIX XXX minimum pixels of alarm Such as alarm Number 2 so the alarm pixel is 2 2 totally 4 pixels 4 Exit Press key LENS to exit Default Level and Threshold Level 1 650 relatively temperature differe...

Page 15: ...device 1 4 SONY EX View HAD CC Lens 3 4 mm to 122 4 mm F1 6 to F4 5 36X Horizontal resolution Color 550TV lines B W 570TV lines Pan Tilt Angle info feedback Support PELCO D protocol Horizontal angle...