10
10
2.3 Quick Guide.
3.2.1 Get infrared imaging
1. Load the battery or power supply.
2. Connect with the monitor if needed.
3. Long press the power button and wait for the camera imaging.
4. Open the lens cap and towards the imager to the target object.
5. Manual/Auto focus the lens to get the best imaging quality.
3.2.2 Measure temperature.
1. Towards the target position at the Cross cursor in the screen, then the
temperature value will be at the Top-Left corner. Long press A key to calibration,
then you can get a better measurement result.
2.
Menu
—Measurement mode—Add area then press A, then press Ok, to add
more area in imaging then to see Highest/Lowest/Average temperature.
3. Press Freeze button to freeze the imaging, then add more point/area/line to
measure more temperature.
4. The temperature will show <xxx or > xxx when the target temperature is higher
or lower than the range, then the user need to change the temperature range.
Summary of Contents for ThermalTronix TT-607FG-HTI
Page 1: ...INFRARED GAS DETECTION THERMAL IMAGING CAMERA ThermalTronix TT 607FG HTI User Manual...
Page 5: ...4 2 Function keys and interface 2 1 Function keys Pic 2 1 1 TT 607FG HTI Top View 2 3 4 5 1 6...
Page 6: ...5 Pic 2 1 2 TT 607FG HTI Back view Pic 2 1 3 TT 607FG HTI Bottom view 12 10 7 9 11 8 14 13...