background image

                                                                                       

 

 

9

 

 

Common Problems: 

1. PWR power supply indicator lamp not lighting  

    Cause: 

1. Power supply not properly connected   

2. Protector tube damaged   

3. Power input tie-line in reverse connection   

4. Internal power supply circuit with failure 

Solution:

 

1

. Check power switch and jack   

2. Replace protector tube   

3. Correct power supply line connection   

4. Returned to the manufacturer for repair. 

 

2. FX (Fiber Link Port) indicator lamp not lighting  

  Cause: 

Optic fiber port link is fault.

 

Solution: 

1. Check fiber optic is link or not. 

2. Check fiber optic loss is high. 

3. Clean the connector of optic interface. 

4. Insert the well connector in place. 

5. Returned to the manufacturer for repair. 

 

3. TP-TX (Ethernet Port) indicator lamp not lighting 

Cause: 

Ethernet port link is fault. 

Solution: 

1. Check Ethernet (RJ45) line is link or not. 

2. Check Ethernet (RJ45) port is loose. 

3. Check the rate of selected media converter 

4. Check the rate of Network. 

Summary of Contents for IT-PMC-3011

Page 1: ...Base T 100Base TX 1000Base T and 1000Base SX LX IT PMC 3011 can conduct mutual conversion between 10Base T 100Base TX 1000Base T twisted pair electrical signals and 1000Base SX LX optical signals This...

Page 2: ...2U 19 14 slots Rack power external Pinout Configuration Power IT PMC 3011 adopt the power supply input is 5VDC external Ethernet RJ45 Optical fiber interface Optical fiber interface Optic fiber interf...

Page 3: ...aight through cable connect PC or server use across over connect cable Switch or HUB MDI PIN 1 2 3 6 connects opposite MID X 1 3 2 6 3 1 6 2 MDI MDI X 10Base T 100Base TX PIN define as follow PIN MDI...

Page 4: ...4 MDI MDI X 1 8 RJ45 TX TX TX RX RX RX RX TX 2 3 6 1 2 3 6 1 1 8 RJ45 TX TX TX RX RX RX RX TX 2 3 6 1 6 1 2 3 TX RX RX TX TX TX RX RX...

Page 5: ...Duplex Mode OFF Half Duplex FLASHING Full Duplex TP TX Ethernet Port OFF Ethernet is not Connected FLASHING Transmitting or Receiving Data BRIGHT Ethernet is Connected Specifications Standards comply...

Page 6: ...External 5VDC input Dimensions 94 0mm 71 0mm 26 0mm Installation support DIN Rail installation Operating temp 10 C to 65 C Storage temperature 20 to 70 C Operating humidity 5 to 95 no condensation War...

Page 7: ...7 Wall mounting installation...

Page 8: ...cation LED table above Note 1 Media Converter is a sensitive electronic item please do handle with extra care on delivery shifting and humidity 2 This unit will be warranty for 5 years 3 Whenever ther...

Page 9: ...ufacturer for repair 2 FX Fiber Link Port indicator lamp not lighting Cause Optic fiber port link is fault Solution 1 Check fiber optic is link or not 2 Check fiber optic loss is high 3 Clean the conn...

Page 10: ...air 4 Network packet loss Solution 1 Check Ethernet rate or full half duplex is matched or not 2 Ethernet RJ45 port is loose contact or optic port is loose contact and soiled 3 Ethernet cable not comp...

Reviews: