Wiring Requirements

 

Be  sure  to  disconnect  the  power  cord  before  installing  and/or 

wiring your Ethernet Switch. 

Calculate the maximum possible current in each power wire and 

common  wire.  Observe  all  electrical  codes  dictating  the 

maximum  current  allowable  for  each  wire  size.  If  the  current 

goes above the maximum ratings, the wiring could overheat may 

causing serious damage to your equipment. You should also pay 

attention to the following items: 

1.  Use  separate  path  to  route  wiring  for  power  and  devices.  If 

power  wiring  and  device  wiring  paths  must  cross,  make  sure 

the wires are perpendicular at the intersection point. 

2.  NOTE:  Do  not  run  signal  or  communications  wiring  and 

power wiring in the same wire conduit. To avoid interference, 

wires  with  different  signal  characteristics  should  be  routed 

separately. 

3.  You  can use the type of signal transmitted through a wire to 

determine  which  wires  should  be  kept  separate.  The  rule  of 

thumb  is  that  wiring  that  shares  similar  electrical 

characteristics can be bundled together. 

4. Keep input and output wiring separated. It is strongly advised 

Summary of Contents for IT-ES308-IU-4F

Page 1: ...n can help system main tenancy personnel monitor the network operation which can work reliably in harsh and dangerous environment IT ES308 IU 4F supports 4 TP ports and 4 fiber ports IT ES308 IU 4F 4...

Page 2: ...arning for power failure and port break alarm 6 Redundant 24VDC power input 12V 48VDC 7 Designed for industrial applications IP30 protection Rugged high strength metal case Panel Layout IT ES308 IU 4F...

Page 3: ...X port 9 100Base FX ports 10 Model name 11 Facility run indication LED 12 System alarm indication LED 13 Port indication LED 14 Power input PWR1 LED 15 Power input PWR2 LED Back panel Units mm Commun...

Page 4: ...Can connect the PC Server Converter and HUB Pin 1 2 3 6 Corresponding connection in MDI 1 3 2 6 3 1 6 2 are used as cross wiring in the MDI X port of Converter and HUB 10Base T 100Base TX are used in...

Page 5: ...ve port connect remote switch s TX transmit port The optical fiber connection supports the line to instruct enhance the reliability of network effectively Suppose If you make your own cable we suggest...

Page 6: ...being supplied to PWR2 ON Power2 is being supplied to OFF Power2 is not being supplied to Alarm ON When the alarm is enabled power and the port s link is inactive OFF Power and the port s link is acti...

Page 7: ...ES308 IU 4F have redundant power input provides one terminal block 4 bits for PWR1 and PWR2 input The redundant power can be used single and used two self governed power to supply to the system PWR1 a...

Page 8: ...ne whether the cables be seemly or not less than 100m according to reasonable scheme 4 Screw nut tool provide by yourself 5 Power need Redundant dual 24VDC 12VDC 48VDC 6 Environment 40 to 75 C Storage...

Page 9: ...ems 1 Use separate path to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point 2 NOTE Do not run signa...

Page 10: ...50nm Alarm output interface One relay alarm output Support power port link and network alarm Indicator Power Port link abnormity alarm indication Technology Standards IEEE802 3 IEEE802 3x IEEE802 3u F...

Page 11: ...to 95 non condensing Approvals EMI FCC Part 15 CISPR EN55022 class A EN61000 4 2 ESD Level 4 EN61000 4 3 RS Level 3 EN61000 4 4 EFT Level 4 EN61000 4 5 Surge Level 4 EN61000 4 6 CS Level 4 EN61000 4 8...

Reviews: