background image

 

 

8

 

Changing the DIP switch status, must re-power. 

 

Installation

 

Before  installation, confirm that the  work environment meet the 

installation  require,  including  the  power  needs  and  abundant 

space. Whether it is close to the connection equipment and other 

equipment are prepared or not.   

Installation require as below 

1.  Avoid  in the sunshine, keep away from the heat  fountainhead 

or the area where in intense EMI.

 

2. Examine the cables and plugs that installation requirements.

 

3. 

Examine whether the cables be seemly or not (less than 100m) 

according to reasonable scheme.

  

4. 

Screw, nut, tool provide by yourself.

 

5. 

Power need: Redundant, dual 24VDC (12VDC~48VDC)   

6. Environment: -40 to 75°C 

    Storage Temperature: -45°C to 85°C 

Relative humidity 10% to 95%   

DIN-Rail Installation 

In order to use in industrial environments expediently, 

IT-ES308-IU-4F adopt 35mm DIN-Rail installation, the 

installation steps as follows:   

1. Examine the DIN-Rail attachment 

2.  Examine  DIN  Rail  whether  be  firm  and  the  position  be 

suitability or not. 

3. Insert the top of the DIN-Rail into the slot just below the stiff 

metal spring. 

4.  The DIN-Rail attachment unit  will  insert  into place as shown 

below. 

 

Summary of Contents for IT-ES308-IU-4F

Page 1: ...n can help system main tenancy personnel monitor the network operation which can work reliably in harsh and dangerous environment IT ES308 IU 4F supports 4 TP ports and 4 fiber ports IT ES308 IU 4F 4...

Page 2: ...arning for power failure and port break alarm 6 Redundant 24VDC power input 12V 48VDC 7 Designed for industrial applications IP30 protection Rugged high strength metal case Panel Layout IT ES308 IU 4F...

Page 3: ...X port 9 100Base FX ports 10 Model name 11 Facility run indication LED 12 System alarm indication LED 13 Port indication LED 14 Power input PWR1 LED 15 Power input PWR2 LED Back panel Units mm Commun...

Page 4: ...Can connect the PC Server Converter and HUB Pin 1 2 3 6 Corresponding connection in MDI 1 3 2 6 3 1 6 2 are used as cross wiring in the MDI X port of Converter and HUB 10Base T 100Base TX are used in...

Page 5: ...ve port connect remote switch s TX transmit port The optical fiber connection supports the line to instruct enhance the reliability of network effectively Suppose If you make your own cable we suggest...

Page 6: ...being supplied to PWR2 ON Power2 is being supplied to OFF Power2 is not being supplied to Alarm ON When the alarm is enabled power and the port s link is inactive OFF Power and the port s link is acti...

Page 7: ...ES308 IU 4F have redundant power input provides one terminal block 4 bits for PWR1 and PWR2 input The redundant power can be used single and used two self governed power to supply to the system PWR1 a...

Page 8: ...ne whether the cables be seemly or not less than 100m according to reasonable scheme 4 Screw nut tool provide by yourself 5 Power need Redundant dual 24VDC 12VDC 48VDC 6 Environment 40 to 75 C Storage...

Page 9: ...ems 1 Use separate path to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point 2 NOTE Do not run signa...

Page 10: ...50nm Alarm output interface One relay alarm output Support power port link and network alarm Indicator Power Port link abnormity alarm indication Technology Standards IEEE802 3 IEEE802 3x IEEE802 3u F...

Page 11: ...to 95 non condensing Approvals EMI FCC Part 15 CISPR EN55022 class A EN61000 4 2 ESD Level 4 EN61000 4 3 RS Level 3 EN61000 4 4 EFT Level 4 EN61000 4 5 Surge Level 4 EN61000 4 6 CS Level 4 EN61000 4 8...

Reviews: