background image

37

3. Using the Unit

EN

Notes on Display Combinations

In addition to the morning average and evening average symbols, the 

unit may also display the morning hypertension symbol if the morning 

average for that week is above the home blood pressure guideline. 

(See Chapter 3 “Using the Unit - Important information” for details.) 

Depending on your measurement results, these may be displayed in 

the following combinations.

Display

Morning 
Average

Morning average from This Week 

with Morning Average Symbol

Morning average from 7 weeks 

ago with Morning Average 

 blinking heartbeat 

 Morning Hypertension 

Symbol

Evening 

average

Evening average from This Week 

with Evening Average Symbol

Evening average from 7 weeks 

ago with Evening Average 

 blinking Heartbeat 

 Morning Hypertension 

Symbol

Average within home blood 

pressure guideline

Average above home blood 

pressure gui Morning 

Hypertension

HEM-1010-E.book  Page 37  Tuesday, November 25, 2008  12:11 PM

Summary of Contents for i-Q132

Page 1: ...ruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ IM HEM 1010 E 02 08 08 1664040 3C EN FR DE IT ES NL RU AR HEM 1010 E_en fm Page 1 Tuesday November 25 2008 1 20 PM ...

Page 2: ...t 19 3 1 How to Sit Correctly When Taking a Measurement 19 3 2 Place Your Arm Through the Arm Cuff 21 3 3 Taking a Reading 23 3 4 Instructions for Special Conditions 31 3 5 Using the Memory Function 32 Care and maintenance 4 Handling Errors and Problems 39 4 1 Error Messages 39 4 2 Troubleshooting 41 5 Maintenance and Storage 44 6 Technical Data 46 7 Some Useful Information about Blood Pressure 48...

Page 3: ...anced Intellisense technology The adjustable cuff angle corrects the body posture which tends to be stooped The elbow rest stabilizes the position and keeps the arm at the most appropriate angle By simply placing the arm through the cuff it automatically wraps around your arm to the appropriate size and starts to measure your blood pressure and pulse rate The monitor stores measurement results for...

Page 4: ...nit Cuff inflation can cause internal bleeding AC Adapter Usage Never plug in or unplug the power cord from the electric outlet with wet hands Battery Usage If battery fluid should get in your eyes immediately rinse with plenty of clean water Consult a doctor immediately Caution Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or p...

Page 5: ...nit Use of unsupported adapters may damage and or may be hazardous to the unit Plug the AC adapter into the appropriate voltage outlet Do not use the AC adapter if the unit or the power cord is damaged Turn off the power and unplug the power cord immediately Battery Usage If battery fluid should get on your skin or clothing immediately rinse with plenty of clean water Use only four AA alkaline bat...

Page 6: ...ction when disposing of the device and any used accessories or optional parts When the unit is not in use or if it is moved etc do not place objects writing implements note books the AC adapter etc in the arm cuff This could cause damage to the cuff lining or the unit and prevent the unit from taking correct readings Do not inflate the arm cuff if your arm is not in place Do not take readings if y...

Page 7: ...ion button E Weekly average Morning Evening button F START STOP button G O I button Power switch H Handle I Elbow rest J Arm cuff K AC adapter jack L Emergency deflation switch Press this to stop measurement in an emergency A B D E F G C DC6V K L I H J Rear view When the arm cuff is open HEM 1010 E book Page 7 Tuesday November 25 2008 12 11 PM ...

Page 8: ...eted or when viewing results stored in the memory indicates blood pressure out of recommended range AA Morning hypertension symbol Indicates blood pressure out of recommended range AB Morning average symbol Displayed when viewing morning averages using the memory function AC Evening average symbol Displayed when viewing evening averages using the memory function AD Average value symbol Displayed w...

Page 9: ...Overview EN Package Contents AF Four AA alkaline LR6 batteries AG AC adapter Instruction manual Quick guide Guarantee card Blood pressure pass AF AG HEM 1010 E book Page 9 Tuesday November 25 2008 12 11 PM ...

Page 10: ...disconnected However the measurement values remain in the memory If you use the AC adapter to power the unit the backlight of the display will light making the display easier to see The backlight will not light when using batteries only By using both the AC adapter and batteries the batteries will last longer Installing the Batteries 1 Make sure that the arm cuff is secured to the unit and turn th...

Page 11: ...tteries so that the positive and negative polarities match the polarities indicated in the battery compartment 4 Put the battery cover back in place Slide the battery cover until it clicks into place HEM 1010 E book Page 11 Tuesday November 25 2008 12 11 PM ...

Page 12: ...off before replacing the batteries Remove the batteries if the unit will not be used for three months or more If the batteries have been removed for more than 30 seconds the Date Time setting will need to be reset See Chapter 2 3 for details Dispose of batteries according to applicable local regulations Four new AA alkaline batteries will last for approximately 250 measurements when used to take s...

Page 13: ...ned for this unit 1 Insert the plug of the AC adapter into the AC adapter jack on the back of the unit 2 Insert the power plug of the AC adapter into a power outlet DC6V 1 2 Power plug AC adapter jack AC adapter plug AC adapter HEM 1010 E book Page 13 Tuesday November 25 2008 12 11 PM ...

Page 14: ...g the date and time setting refer to Adjusting the Date and Time Setting The weekly average buttons are used to set the date and time Use the buttons as described below to adjust the date and time setting Evening average button Press this button to increase the value for the date time setting Morning average button Press this button to decrease the value for the date time setting 1 Press the O I b...

Page 15: ... 2030 If the year reaches 2030 it will return to 2007 3 Press the MEMORY button to confirm the setting when the desired number appears on the display The year is set and the month digits flash on the display 4 Press the weekly average buttons to adjust the month setting Press the Evening average button once to increase the setting by one month Press the Morning average button once to decrease the ...

Page 16: ...g average button once to increase the setting by one day Press the Morning average button once to decrease the setting by one day Hold the buttons down to increase decrease the digits rapidly 7 Press the MEMORY button to confirm the setting when the desired number appears on the display The day is set and the hour digits flash on the display Example when October has been set as the month HEM 1010 ...

Page 17: ... hour and minutes then press the MEMORY button to confirm the setting When the date and time settings have been set the display changes to that shown to the above 9 Press the O I button to turn the power off Note You can also start taking readings immediately rather than turn the unit off HEM 1010 E book Page 17 Tuesday November 25 2008 12 11 PM ...

Page 18: ...blems with morning and evening weekly averages stored in the memory 1 Press the O I button to turn the power off 2 Turn the unit on then press and hold the MEMORY button for three seconds or longer when the standby display shown right appears 3 The year setting flashes on the display Refer to Chapter 2 3 to adjust the settings for the date and time Standby display When the arm cuff is closed HEM 1...

Page 19: ... 30 minutes before taking a measurement Do not move or talk during measurement Correct Posture Remove tight fitting clothing from your upper arm and any thick clothing such as a sweater Do not place the cuff over thick clothes and do not roll up your sleeve if it is too tight Sit upright with your back straight Place the center of the arm cuff so that it is at the same height as your heart The gap...

Page 20: ...y please check with your physician which arm to use for your measurement Incorrect Posture If you are leaning forwards this can put pressure on your stomach which could cause the measurement results to be incorrect Readings cannot be taken correctly in the following cases Arched back leaning forwards Sitting cross legged Sitting on a sofa or at a low table so that you tend to lean forward If the u...

Page 21: ...with your bare arm or light clothing Note Remove thick clothing from your upper arm Do not take readings over thick clothes or rolled up sleeves 1 Press the Arm cuff release button to open the arm cuff The arm cuff can be moved within the range shown to the right Arm cuff release button HEM 1010 E book Page 21 Tuesday November 25 2008 12 11 PM ...

Page 22: ...N distributor or Customer Services as mentioned on the package 3 Place your elbow on the elbow rest 4 Check that you are sitting correctly Refer to Chapter 3 1 Rest your elbow here Taking measurements on the right arm Refer to steps 2 and 3 above and place your right arm through the arm cuff as shown Right arm HEM 1010 E book Page 22 Tuesday November 25 2008 12 11 PM ...

Page 23: ...re is known to be above 170 mmHg refer to Chapter 3 4 1 Sit comfortably and relax If you feel tense take a few deep breaths 2 Press the O I button to turn the power on The unit is turned on and the display appears as shown below 3 Press the user ID selection button to select the desired user Today s date Current time All items light up Standby display HEM 1010 E book Page 23 Tuesday November 25 20...

Page 24: ...ed in the memory 4 Check that you are sitting correctly If you are not sitting correctly the symbol appears on the display The symbol disappears when you are in the correct posture Start measurement only after checking that you are sitting correctly Note Depending on the angle of the arm cuff the symbol will appear on the display even if your arm is not in the arm cuff Guest User A User B Angle of...

Page 25: ...rm cuff inflation is insufficient Automatic re inflation occurs only once Display During Measure ment The arm cuff adjusts to the size of your arm Flashes in a rotating fashion Inflation starts after the arm cuff has adjusted to the size of your arm Ready for measurement Measurement ends Measurement displayed as the arm cuff deflates Inflates to the required pressure HEM 1010 E book Page 25 Tuesda...

Page 26: ...easurement will stop if any button is pressed DC6V Important If inflation does not stop when the O I START STOP or any other button is pressed Press the emergency deflation switch on the back of the unit Note The clock will also stop if you press the emergency deflation switch Reset the date and time Emergency deflation switch HEM 1010 E book Page 26 Tuesday November 25 2008 12 11 PM ...

Page 27: ...tions of your doctor If the or symbols are displayed Please repeat measurement In some cases it may not be possible to take measurement correctly SYS DIA Pulse If displayed Incorrect posture during measurement Sit correctly and take the measurement again Refer to Chapter 3 3 4 Note The symbol will disappear in a few seconds but may appear again depending on the cuff angle at the time If is display...

Page 28: ...tion prior to taking the blood pressure measurement Repeat the measurement after your arm is relaxed again Refer to Chapter 3 3 7 Remove your arm and return the arm cuff to its original position The arm cuff will click into place 8 Press the O I button to turn the power off Note If you forget to turn the power off the unit will turn itself off automatically after five minutes HEM 1010 E book Page ...

Page 29: ...rtbeats can influence the results of the measurement The irregular heartbeat algorithm automatically determines if the measurement is usable or needs to be repeated If the measurement results are affected by irregular heartbeats but the result is valid the result is shown together with the irregular heartbeat icon If the irregular heartbeats cause the measurement to be invalid no result is shown I...

Page 30: ...symptoms are skipped heartbeats premature contraction an abnormally rapid tachycardia or slow bradycardia pulse This can be caused by heart disease aging physical predisposition stress lack of sleep fatigue etc Arrhythmia can only be diagnosed by a doctor through a special examination Whether the appearance of the irregular heartbeat symbol in the results indicates arrhythmia or not can only be de...

Page 31: ... hold the START STOP button until the cuff inflates 30 to 40 mmHg higher than your suspected systolic pressure Note You cannot inflate the cuff above 299 mmHg An error will be displayed if you try to inflate the cuff above 299 mmHg 4 Release the START STOP button when the cuff has been inflated to the desired pressure The cuff starts to deflate and measurement starts 5 The rest of the procedure is...

Page 32: ...orning averages and 8 weeks of evening averages for each user A and B Average Function The unit calculates the average reading based on the three most recent sets of measurement values taken within 10 minutes of the most recent reading Note If two sets of measurement values are stored in the memory for the 10 minutes period the average is based on the two sets of measurement values If one set of m...

Page 33: ...rement values on the screen Note After the memory number is shortly indicated the date and time are alternately displayed with the measurement values The values are displayed from the most recent to the oldest by pressing the MEMORY button Press and hold the MEMORY button to display the values faster 5 Press the O I button to turn the unit off Alternating display HEM 1010 E book Page 33 Tuesday No...

Page 34: ...ekly Averages The unit calculates and displays weekly averages for measurements taken in the morning and evening within 8 weeks for each user A and B Note The week begins Sunday at 4 00 HEM 1010 E book Page 34 Tuesday November 25 2008 12 11 PM ...

Page 35: ... up to three measurements taken within 10 minutes of the last measurement of the evening First measurement of the morning Within 10 minutes 9 59 4 00 Measurements of the morning Up to 3 measurements Morning Blood Pressure Measurement Measurement Measurement Measurement Measurement Measurement Sunday Monday Tuesday Wednesday Thursday Friday Saturday Measurements of the evening Last measurement of t...

Page 36: ...layed by pressing the morning average button or the evening average button It is important to check both morning and evening average of the same week 4 Continue to press the morning average button or the evening average button to display the previous weeks The unit displays 1 WEEK for the previous week to 7 WEEK for the oldest set of averages Note If there are not enough measurements taken in a we...

Page 37: ...the following combinations Display Morning Average Morning average from This Week with Morning Average Symbol Morning average from 7 weeks ago with Morning Average Symbol blinking heartbeat Symbol Morning Hypertension Symbol Evening average Evening average from This Week with Evening Average Symbol Evening average from 7 weeks ago with Evening Average Symbol blinking Heartbeat Symbol Morning Hyper...

Page 38: ...ues Stored in the Memory The values stored in the memory are deleted by user ID You cannot partially delete values stored in the memory All values for the user you select will be deleted 1 Press the O I button to turn the power on 2 Press the user ID selection button to select the user ID A or B 3 While holding the MEMORY button press the START STOP button simultaneously for more than 2 seconds an...

Page 39: ...e arm cuff correctly Place your arm correctly Refer to Chapter 3 2 Are rolled up sleeves squeezing the arm Remove clothing from your upper arm and place your arm through the cuff Refer to Chapter 3 2 Is air leaking from the arm cuff Contact your OMRON distributor or Customer Services as mentioned on the package Movement during measurement Check that the heartbeat symbol is lit then keep still and ...

Page 40: ...lace all four AA batteries with new ones Refer to Chapter 2 1 A malfunction has occurred Contact your OMRON distributor or Customer Services as mentioned on the package Battery low symbol blinks or appears continuously Er displayed HEM 1010 E book Page 40 Tuesday November 25 2008 12 11 PM ...

Page 41: ... your OMRON distributor or Customer Services Cuff is not inflated Is air leaking from the arm cuff Contact your OMRON distributor or Customer Services The unit operates normally and measurements appear to be taken but Measurements taken by a doctor are higher or lower Measurement results are different each time Refer to Chapter 7 Power is turned off during measurement The date and time are reset T...

Page 42: ...ed for more than 30 seconds Replace the batteries within 30 seconds No display appears when O I button is pressed The batteries are empty Replace the batteries Refer to Chapter 2 1 The batteries are installed incorrectly Insert the batteries correctly Refer to Chapter 2 1 The AC adapter was disconnected from the unit when using the AC adapter only Connect the AC adapter Refer to Chapter 2 2 The AC...

Page 43: ...urn the power off then repeat measurement Replace the batteries If the problem persists contact your OMRON distributor or Customer Services as mentioned on the package Problem Cause Remedy HEM 1010 E book Page 43 Tuesday November 25 2008 12 11 PM ...

Page 44: ...ons It is recommended that you have the unit inspected every two years to ensure it is accurate and functioning correctly Consult the OMRON distributor or Customer Services as mentioned on the package for further details Do not subject the unit to strong shocks or vibrations for example dropping the unit on the floor Do not use volatile liquids to clean the unit THE UNIT AND THE CUFF SHOULD BE CLE...

Page 45: ... be exposed to chemical or corrosive vapours Storage Precautions Store the unit with the arm cuff closed Remove the batteries if the unit will not be used for a long time 3 months or longer When the unit is not in use or if it is moved etc do not place objects writing implements note books the AC adapter etc in the cuff This could cause damage to the cuff lining or the main unit and prevent the un...

Page 46: ...od Measurement Range Pressure 0 mmHg to 299 mmHg Pulse 40 to 180 min Accuracy Pressure 3 mmHg Pulse 5 of display reading Inflation Fuzzy logic controlled by electric pump Deflation Automatic pressure release valve Pressure Detection Capacitive pressure sensor Memory 84 Measurements with date and time for each user A and B Power Source 4 AA alkaline batteries 1 5V or AC DC adapter Included Input 10...

Page 47: ...orrect operation of the medical device and create a potentially unsafe situation Medical devices should also not interfere with other devices In order to regulate the requirements for EMC Electro Magnetic Compatibility with the aim to prevent unsafe product situations the EN60601 1 2 standard has been implemented This standard defines the levels of immunity to electromagnetic interferences as well...

Page 48: ...by a doctor can cause anxiety which is itself a cause of high blood pressure As a variety of conditions affect blood pressure a single measurement may not be sufficient for an accurate diagnosis Many factors such as physical activity anxiety or the time of day can influence your blood pressure Thus it is best to try and measure your blood pressure at the same time each day to get an accurate indic...

Page 49: ...ote There is no universally accepted definition of hypotension However those having the systolic pressure below 100 mmHg are assumed as hypotensive mmHg 200 150 100 50 6 12 18 24 Example fluctuation within a day male 35 years old Time of day Upper curve systolic blood pressure Lower curve diastolic blood pressure 80 180 160 140 130 120 85 90 100 110 Diastolic blood pressure mmHg Systolic blood pre...

Page 50: ...n healthcare com Production facility OMRON DALIAN CO LTD Economic Technical Development Zone Dalian 116600 China Subsidiary OMRON HEALTHCARE UK LTD Opal Drive Fox Milne Milton Keynes MK15 0DG United Kingdom OMRON Medizintechnik Handelsgesellschaft mbH John Deere Str 81a 68163 Mannheim Germany www omron medizintechnik de OMRON SANTÉ FRANCE SAS 14 rue de Lisbonne 93561 Rosny sous Bois Cedex France E...

Reviews: