SPECIFICATIONS

Range

:

25' (7.6 m) maximum

No minimum range

Operating Temperature:

32

o

 to 120

o

 F (0

o

 to 49

o

 C)

Storage: -4

o

 to 122

o

 F

(-20

o

 to 50

o

 C)

Alarm Duration:

5 seconds (unaffected by

alarm LED latching)

Alarm Relay:

Form C

125 mA maximum

25 VDC maximum

Tamper Switch:

Combination cover and

wall tamper

25 mA maximum

24 VDC maximum

Power Requirements:

8 - 14 VDC;  25 mA typical at

12 VDC, 35 mA max

AC  Ripple:    4  Volts  peak-to-peak

at Nominal 12 VDC

RFI Immunity:

30 V/m, 10 MHz - 1000 MHz

ESD Immunity:

10 kV,

Discharges of either polarity to

exposed surfaces

Dimensions:

3.86" H x 2.44" W x 0.86" D

(98 mm  x 62 mm x 21.8 mm)

Weight:

3.2 oz.,  (90 g)

Packaged Product: 4.1 oz, (116 g)

FCC Notice:

  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15

of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installa-

tion.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the

instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not

occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be

determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the

following measures: 1) Reorient or relocate the receiving antenna, 2) Increase the separation between the equipment and receiver,

3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  The installer can also

consult an experienced radio/television technician for additional suggestions, if necessary.

IC Notice:

 This digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.  Cet appareil

numèrique de la Classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.

Protected Glass:

Minimum size for all types is 11"

(28 cm) square; Glass must be

framed in the wall of the room or

mounted in a barrier of 36" (0.9 m)

minimum width.

Thickness

Type

Minimum

Maximum

Plate

3/32" (2.4 mm)

1/4" (6.4 mm)

Tempered

1/8" (3.2 mm)

1/4" (6.4 mm)

Laminated

1

1/8" (3.2 mm)

9/16" (14.3 mm)

Wired

1/4" (6.4 mm)

1/4" (6.4 mm)

Coated

2

1/8" (3.2 mm)

1/4" (6.4 mm)

Sealed Insulating

1

1/8" (3.2 mm)

1/4" (6.4 mm)

2

For glass coated on the inner surface with 3M

®

 scotchtint™ type RE35NEARL or Hardglass

®

Security Film, reduce maximum range to 15 feet (4.6 m).

1

Laminated and sealed insulating glass types are protected only if both plates of glass are

broken.

Accessories:

FG-701 Glassbreak Simulator

FG-SP1 Spacer Plate -

depth 0.6" (15.2 mm)

IntelliSense is a registered trademark of Honeywell, Inc.

Other trademarks are the property of their respective owners.

Note:

  The FG-1025 Glassbreak Detector is designed for primary

perimeter security.  For a complete security system, additional

interior protection devices are recommended.

Note:

  For UL certificated installations, this detector must be

connected to a UL Listed power supply or UL Listed control

unit capable of supplying a minimum of four hours of standby

power.

Note:

 The ULC label or listed marking on a product is the only

evidence provided by Underwriters Laboratories of Canada to

identify products that have been produced under the Listing

and Follow-up service.

Approvals/Listings:

FCC verified

IC verified

UL listed

ULC listed

CE Mark

(EMC Directive: residential,

commercial, light industrial)

C-Tick

Summary of Contents for FG-1025

Page 1: ...omplete push excess wire back into the wall NOTE If end of line resistors are required wire as shown in Figures 2c and 2d NOTE For proper wiring methods refer to the National Electrical Code NFPA 70 DIP Switch Terminal Blocks Tamper Switch Power 25 mA at 12 VDC LEDs Wire Entry Hole Figure 1 Tamper Alarm Form C MOUNTING LOCATION The FG 1025 can be mounted in corners on walls or on ceilings Refer to...

Page 2: ...ront of the simulator at the detector and press the red start button Refer to Figure 6 You should hear a short buzz from the simulator and the green LED on the FG 1025 should begin flashing about once per second to indicate it is in Test Mode NOTE In Test Mode the LED disable switch is overridden SWITCH OFF ON LATCH Red alarm LED Red alarm LED lights for 5 seconds latches ON when when detector ala...

Page 3: ...test pads at location S3 on the PCB see Figure 1 This will activate Test Mode Make sure to close the front cover of the FG 1025 before beginning test To test the FG 1025 1 Place the detector in Test Mode as described above 2 Set the FG 701 switches to the TEST and FLEX positions 3 Press the red start button The simulator will click on and start an eight second armed period 4 Position the FG 701 ne...

Page 4: ...which the receiver is connected The installer can also consult an experienced radio television technician for additional suggestions if necessary IC Notice This digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil numèrique de la Classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada Protected Glass Minim...

Reviews: