background image

PRODUCT  SPECIFICATIONS

Range:

11 m x 11 m

Alarm relay:

Energized Form A

125 mA, 25 VDC, 20 Ohm series resistor

Tamper:

NC, 50 mA, 24 VDC

Power  requirements:

7.5 - 16 VDC

25 mA typical, 30 mA maximum, 12 VDC

AC Ripple: 3 V peak-to-peak at nominal 12 VDC

Microwave  frequencies:

24.125 GHz

PIR  white  light  immunity:

6,500 Lux typical

Fluorescent light filter:

50 Hz

RFI  immunity:

30 V/m,10 MHz - 1000 MHz

Operating  temperature:

-10

to +55

o

 C  (14

to +131

F)

5 - 95% relative humidity (non-condensing)

Self-test intervals:

Microwave Supervision

Every  5  seconds

PIR self-test

Once  every  hour

Temp.  Comp.

Every  30  seconds

PIR  fields-of-view:

Standard  Wide  Angle  Lens

22 long range edges

12 intermediate edges

6 lower edges

* 4 look-down edges

Dimensions:

11.9 cm H x 7.1 cm W x 4.2 cm D

Sensitivity:

Standard 3 - 4 steps

Harsh 4 - 5 steps

© 2001 IntelliSense

®

  • IntelliSense and DUAL TEC are registered trademarks of Honeywell, Inc.

All other trademarks are the properties of their respective owners. All rights reserved.

5-051-661-00  Rev  A

LED  INDICATORS

DIP SWITCH SETTINGS (SW1)

Factory default settings are shown in grey.

DETECTION  PATTERNS

DT-7435 

EU 

DUAL 

TEC

®

 M

otion 

Sensor 

Product 

Information

TROUBLE  SHOOTING
Problem: 

 Red LED is flashing rapidly.

Explanation: 

 The sensor is in one of three conditions:

Microwave supervision failure:  The sensor  continues operating using PIR

as the only detection method. When detection occurs on the PIR channel,

the alarm relay will latch open until the Microwave trouble is removed.
PIR self-test failure:  Alarm relay does not actuate.
Temperature compensation failure:  When alarm occurs, the alarm relay

will latch open until the trouble is cleared.

Solution:

  Power down the sensor or enter zone finder mode which will

perform self-test. If the trouble does not clear, replace the sensor.

Power  Up

Slow

Blink

OFF

OFF

DT-7435 EU Top View

Wide Angle Lens

11 m

SPECIAL  INSTRUCTIONS  FOR  INSTALLATIONS  CONTAINING  PETS

To take full advantage of the pet immunity the following guidelines should be

followed:

• Mount the center of the detector 2.3 m high.
• Ensure that the look-down mask is in place (see Step 2).
• Mount where animals cannot come within 1.8 m of the detector by

climbing on furniture, boxes or other objects.

• Do not aim the detector at stairways that can be climbed by animals.

Notes:

This sensor will provide immunity to false alarms for an individual animal or a

group of animals whose total weight is equal to or less than 45 kilograms.

DT-7435EU

Side View

Wide Angle Lens

*

 Look-down fingers are enabled

only when the look-down mask is

removed (see Step 2).

LED

Red

Yellow

Green

Normal

ON

Alarm

ON

Microwave

ON
PIR

Trouble

Fast

Blink

OFF

OFF

Zone Finder

OFF

ON

Microwave

ON
PIR

OPERATION

S

witch

1
2

OFF

 Harsh Sensitivity

LED  Disabled

ON

Standard  Sensitivity

LED  Enabled

Reviews: