8.11
System
Protections
The ToughPower is equipped with software and hardware protections that will ensure the internal
electronics components and the connected battery remain within safety operating parameters. If the unit
enters any protection mode or detects any faults the status LED located on the front of the ToughPower
(next to the Master Switch) will pulse RED to notify this condition as detailed in section
FAULT LED
Indication
.
Under
normal
operation
the
LED
will
turn
on
GREEN.
Table below summarizes what features are enabled and available depending on the active protection
mode.
PROTECTION
MODE
INPUTS
POWER
OUTLETS
LED
USB
MAINS
CAR
SOLAR
EXT
AC
DC
NORMAL
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
LOW-VOLTAGE
ENABLED
ENABLED
ENABLED
DISABLED
DISABLED
DISABLED
DISABLED
ENABLED
*
RECOVERY
ENABLED
ENABLED
ENABLED
DISABLED
DISABLED
DISABLED
DISABLED
ENABLED
*
OVER-TEMP
DISABLED
DISABLED
DISABLED
DISABLED
DISABLED
ENABLED
DISABLED
ENABLED
OVER-TEMP-LCD
DISABLED
DISABLED
DISABLED
DISABLED
DISABLED
ENABLED
DISABLED
ENABLED
Note: * When the system is in LOW VOLTAGE & RECOVERY modes, the two USB ports are still powered so
that
you
can
use
them
for
emergency
only.
8.11.1
Low
Voltage
Protection
The built-in sensors monitor the Battery Voltage constantly. If during
usage the Battery Voltage drops below the pre-set limits defined for
each battery type (see table below) the ToughPower will
automatically activate the LOW VOLTAGE Protection Mode. All AC
and DC Power Outlets are automatically
disabled to isolate and
protect the battery from damage. All Charging Inputs remain
open to
accept Charging Power as soon as it becomes available. The LCD will
display
the
following
message
to
notify
this
event.
Type
Low
Voltage
Cut-off
(V
DC
)
LEAD/GEL
10.8
CALCIUM
10.8
AGM
10.8
LITHIUM
LiFePO4
11.6
For Lead-Acid family battery types the Low Voltage limit is dynamic depending on the System Load to
compensate
for
the
internal
battery
losses
associated
with
these
types
of
batteries.
Page