Product Overview 

The Intellinet 19" Intelligent 8-Port PDU is designed to provide steady power and keep network 
equipment active. It monitors electricity and environmental status to provide users with relevant 
information and alert them of potential power overloads. The user can readily view equipment 
status and turn on or shut off each output port by accessing the device through the network.  

 

Product Features: 

  Eight power outputs (total current, 16 A) 

  Current, voltage (total input) measurements 

  Built-in temperature and humidity sensors to monitor the environment 

  Embedded technology, Java support, web browsing 

  Two-level programmable values for warning and overload 

  Circuit-delay time setting to prevent power surges 

  LED indicators for the power supply on each switch 

  LED digital display to show the current value of voltage and current 

  Local query buttons of PDU equipment 

  Built-in lightning- and voltage-surge resistance to effectively protect connected equipment 

 

Product Specifications:  

  Voltage input: 110-240 V, 50/60 Hz 

  Voltage output: 110-240 V, 50/60 Hz 

  Input socket type: IEC320 C20, *1 bit 

  Output socket type: IEC320 C13, *8 bits 

  Protection: 16 A overload protection, lightning protection 

  Voltage measurement range: 90-264 VAC, resolution 1 V 

  Current working range: 0-20 A, resolution 0.1 A 

  Temperature measurement range: 20% -90% RH, resolution 1% RH 

  Humidity measurement range: 0 

-50 

, resolution 1 

 

Summary of Contents for 163682

Page 1: ...MH 163682_UM 0717_REV 5 01 19 Intelligent 8 Port PDU User Manual Model 163682...

Page 2: ...r Intellinet reserves the right to make changes to any software or hardware to improve reliability function or design at any time without notice The information contained herein is subject to change w...

Page 3: ...ecifications 4 Chapter 2 Product Diagram 5 Key 5 Chapter 3 Functions 6 Basic Functions 6 Interface Functions 6 Login Control Interface 6 PDU System Information 7 Power Port Control 7 ON and OFF Time D...

Page 4: ...nt Embedded technology Java support web browsing Two level programmable values for warning and overload Circuit delay time setting to prevent power surges LED indicators for the power supply on each s...

Page 5: ...apter 2 Product Diagram 1 2 3 4 5 6 Key 1 Power Input Socket IEC320 C20 2 Output Socket IEC C13 3 Reset Key 4 Function Key check the machine IP address 5 Display Panel voltage current temperature humi...

Page 6: ...ess voltage and current The default IP address is 192 168 0 10 3 Check the temperature and humidity Press the FUNC button after the display shows the IP address to reveal the temperature and humidity...

Page 7: ...off any of the eight outputs through this interface Start all click on the drop down menu from the Operation box choose Start and click the Apply button Shut off all click the drop down menu from the...

Page 8: ...ight way output through a network Threshold Value Setting Click Threshold value in the configuration box on the left side of the interface The screen displays the following The meaning of each input i...

Page 9: ...Click Network in the configuration box on the left side of the interface The screen displays the following Users can adjust values here The meaning of each input in the above dialog box is as follows...

Page 10: ...o puede desecharse se con el resto de residuos no clasificados Desh gase de este producto devolvi ndolo a su punto de venta o a un punto de recolecci n municipal para su reciclaje Fran ais Ce symbole...

Page 11: ...y Statements FCC Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of Federal Communications Commission FCC Rules These limits...

Page 12: ...intellinetnetwork com...

Reviews: