Intelligent PM SERIES Operation Manual Download Page 2

1. INSTALLATION 

 

Check and make sure that the following 

accessories are included: 

This Operation Manual 

Indicator x 1 

Mains adapter x 1 

Assembled platform x 1 

Stainless steel platform cover x 1 

L shape indicator platform mount support x 1 

U shape indicator wall mount support x 1 

Pillar, pillar mounting set + screws and tool 

set x 1 (Option) 

Contact your dealer if any items missed. 

 

2. Insert stainless platform cover into the 

platform in the same direction as the 

platform. Always insert the platform cover 

to the platform gently, no excessive force 

is needed. 

 

3. Fixing the Indicator 

3.1 Platform Mount 

3.1.1 Connect the cable plug from the 

platform to the indicator receiving 

plug. 

3.1.2 Secure the connection firmly by 

turning the plug screw in clockwise 

direction.  

3.1.3 Insert the indicator to the L shape 

support, with the back of the indicator 

against the platform. 

NOTE:  

The indicator could be mounted to the platform 

in either longitude or latitude direction. 

Default mounting is in longitude direction. 

To change mounting direction, remove the 

screws of the platform mount support 

underneath the platform, then move the 

support to the alternate mounting area and 

fix it with the screw. 

 

3.2 Wall Mount 

3.2.1 Install the supplied U shape support 

to a strong wall surface. Secure the 

support to the wall with screws 

supplied. In no circumstance the 

extended cable length should excess 

100cm. 

3.2.2 Connect the cable plug from the 

platform to the indicator receiving 

Summary of Contents for PM SERIES

Page 1: ...EFULLY BEFORE ATTEMPT TO OPERATE THE SCALE APRIL 2003 REV 3 Specifications subject to change without prior notice CONTENTS 1 INSTALLATION 2 SPECIFICATIONS 3 KEYBOARD LAYOUT AND DESCRIPTION 4 INSTRUCTI...

Page 2: ...m the platform to the indicator receiving plug 3 1 2 Secure the connection firmly by turning the plug screw in clockwise direction 3 1 3 Insert the indicator to the L shape support with the back of th...

Page 3: ...le through the pillar very carefully 3 3 5 Connect the cable plug to the indicator receiving plug 3 3 6 After plugs are connected lock the plugs by turn the plug screw in clockwise direction 3 3 7 Ins...

Page 4: ...he mains adapter is used Operatin g Temp 0 400 C 32 1040 F TO COMPLY WITH THE LAW THE POUND UNIT WOULD BE DISABLE IN CERTAIN COUNTRIES PLEASE CONTACT YOUR LOCAL FOR MORE INFORMATION SPECIFICATIONS SUB...

Page 5: ...ated weight in memory SIGNS 8 LO BAT SIGN When this sign is on recharge the scale immediately 9 ZERO SIGN An arrow will appear and point at this sign to indicate a zero weight status 10 TARE SIGN An a...

Page 6: ...RO to confirm and return to normal operation status If the pound weight is selected Press MODE to shift among kg 1b and 1b oz during operation 4 3 2 Select Auto Hold Status The default Hold setting is...

Page 7: ...n disappears 4 5 Zero the Weight Displayed When Unloaded If zero weight value is not displayed when the scale is unloaded press ZERO to reset weight to zero 4 6 PLACING A LOAD Always place a load to t...

Page 8: ...eight display is stable press M to save Scale Displays P 1 and the M arrow sign appears indication total number of total entries and the memory function is being employed 4 9 2 Recall Weight Accumulat...

Page 9: ...ug to the indicator receiving plug CHECK Is the platform cover placed correctly ACTION Check and insert the platform again CHECK Is anything load applied to platform ACTION Remove all loads applied to...

Page 10: ...of the scale ACTION Removed loads on platform and check again 6 DAILY CARE AND MAINTENANCE 6 1 Clean the scale with a soft and damp cloth if necessary with a mild detergent 6 2 Do not sue any harsh ab...

Page 11: ...7 INSTALLATION DIAGRAM Diagram 1 W shape mounting Diagram 2 U shape wall mounting Diagram 3 Pillar mounting Diagram 4 Pillar mounting accessories...