-4-
Electric Lock Connection
Electric lock can be powered from Door Station
if:
1.
Electr
ic
lock
is ‘
Power-on-to-unlock
’
type
2.
The lock is 12V, and holding current
is
less
than 250mA
3.
lock control is not timed from Exit Button
(EB)
The
‘
Unlock
Mode
’
Parameter
would be
0
(default
, no need extra programming
)
EB
*
LOCK
BUS
PL
S+
S-
Jumper position 2-3
1 2 3
LOCK
Take off the Jumper
POWER
SUPPLY
BUS
PL
S+
S-
Automated Gates and Magnetic Locks
1.
Connect low voltage box of the gate according the
diagram
. Use power supply for magnetic lock
according lock specs
2.
The inside relay contact is restricted to AC or DC
24V/1A
3.
The jumper must be taken off
T
he
‘
Unlock
Mode
’
parameter for ‘
Power-on-to-unlock
’
would be
0
(default, no need extra programming)
T
he
‘
Unlock
Mode
’
parameter for ‘Power-off-to-unlock’
would be
1
(needs extra programming via monitor
)