9
8
Power Path Module Data
PPM Data
6
6
6.1
6.2
6.2.1
6.2.2
Output UART data format
The communication port has a serial format. The parameters are as follows:
UART:
9600 baud, 8 data bits, 1 stop bit, and no parity
Format:
There are 14 messages in the data stream
A typical message from the UART will be formatted as follows:
<6708,85.0,75.0,2,00000000,85.0,78.0,2,00000000,85.0,1800.0,45.00,40.00,249>
SD card data
The SD card contains data from the operation of the fuel cells.
SD card data designation
On the SD card there will be a folder called
Data
containing .csv files with the
columns having the following headings:
Power Path Module fault codes
The fault codes for the PPM as stored in the PPM SD card are shown below.
For fault codes from the FCPM SD card refer to the FCPM User Manual.
The naming of the unit is covered in N type rows. Serial number will be displayed as
a 15 digit alpha numeric. The software version will be displayed in the format X.XX.
Data title
Units
Description
Time
Secs
Time from when PPM
powered on
FCPM #1 Tank Pressure
%
0 to 100 (5Bar to 300Bar)
FCPM #1 Battery Level
%
0 to 100 (19.6V to 24V)
FCPM #1 State
N/A
0 to 8
FCPM #1 Fault Codes
N/A
00000000 to 80000000
FCPM #2 Tank Pressure
%
0 to 100 (5Bar to 300Bar)
FCPM #2 Battery Level
%
0 to 100 (19.6V to 24V)
FCPU #2 State
N/A
0 to 8
FCPU #2 Fault Codes
N/A
00000000 to 80000000
Tank Pressure
Bar
0 to 300
Output Power
Watt
0 to 2800
Output Voltage
Volt
0 to 50
Output Current
Amp
0 to 50
Bit Statuses (5×DI, 1×DO)
N/A
000000 to 11111
Data title
Units
Description
FCPM #1 Tank Pressure
%
0 to 100 (5Bar to 300Bar)
FCPM #1 Battery Level
%
0 to 100 (19.6V to 24V)
FCPM #1 State
N/A
0 to 8
FCPM #1 Fault Codes
N/A
00000000 to 80000000
FCPM #2 Tank Pressure
%
0 to 100 (5Bar to 300Bar)
FCPM #2 Battery Level
%
0 to 100 (19.6V to 24V)
FCPU #2 State
N/A
0 to 8
FCPU #2 Fault Codes
N/A
00000000 to 80000000
Tank Pressure
Bar
0 to 300
Output Power
Watt
0 to 2800
Input Voltage
Volt
0 to 50.
The sum of the output
voltages for the two FCPMs
Output Current
Amp
0 to 50
Output Voltage
0 to 50 Volt
Output voltage from the
PPM
5xDI, 1xDO bit statuses
N/A
000000 to 11111
Software Version
N/A
1.00 to 9.99
PPM Serial Number
N/A
15 characters (alphanumeric)
SPPM Fault Code
N/A
00000000 to 80000000
Fault code
Description
Condition
Sustained delay (s)
80000000
The Master Output FET has
failed short
Master Output not enabled
and voltage difference across
the Ideal Diode less than 3V
0.50
40000000
The Master Output FET has
failed to switch on (allow
current)
Master Output enabled and
voltage difference across the
Ideal Diode greater than 3V
0.50