v80G – Marine Satellite Communication System
52
10. Press RIGHT arrow key to display the real-time diagnostic result.
The real-time diagnostic code will be displayed automatically if there is any error found
during the system operation. However, this page will not be displayed if there is no error
message.
11. Press FUNCTION key to erase diagnostic error message.
[ D I A G N O S T I C ]
S E N S O R B O X
C O D E 1 0 9
R E S U L T S : F A I L E D
F N
E R A S E D I A G N O S T I C E R R O R L O G ?
Y E S
N O
Erase
Error message
Real-time
diagnostic
result
USB
9. Touch OK key to upgrade firmware.
Refer to the error messages below if any errors occur.
UPGRADE FIRMWARE
- FIRMWARE FILE NOT FOUND: the system cannot find the FWP file.
- INVALID FIRMWARE: the file is not in a recognizable FWP format.
- MORE THAN 1 FILE EXIST: there is more than 1 firmware file that exists in the specified
folder in the USB flash drive.
- CHECK USB CONNECTION: the USB flash drive is not connected.
COPY LOG DATA
- COPY LOG DATA TO USB [30%]: display the copy progress in percentages.
- NOT ENOUGH SPACE IN USB: USB is out of memory
- CHECK USB CONNECTION: the USB flash drive is not connected.
Upgrade
the system
U P G R A D E ?
Y E S
N O
Summary of Contents for v80G
Page 1: ...Global Leader In Marine Satellite Antenna Systems v80G Installation and Operation User Guide...
Page 2: ...v80G Marine Satellite Communication System 2...
Page 4: ......
Page 5: ......
Page 6: ...INDEX...
Page 8: ...v80G Marine Satellite Communication System 8...
Page 14: ...v80G Marine Satellite Communication System 14...
Page 29: ...29 INSTALLING THE ANTENNA...
Page 34: ...v80G Marine Satellite Communication System 34...
Page 112: ...v80G Marine Satellite Communication System 112...