77
PC CONTROLLER SOFTWARE
PC to ACU Communication Setup
Enter “Communication Information” menu to setup the data communication
between the PC and the ACU.
• Access ACU through Serial Communication
- Connect a 9 pin serial cable from the PC INTERFACE connector on the ACU to
the 9-pin serial port on the PC. Use USB-Serial Adapter if there is no 9-pin serial
port on the PC.
- Execute PC Controller Software by inserting the supplied CD-ROM into the CD-
ROM drive of the PC.
- The baud rate of the ACU is 19200.
- Select a COM port which is not occupied by other devices.
- Click Connect button
• Access ACU through Network Communication
- Turn off wireless connection while using this method.
- Execute PC Controller Software by inserting the supplied CD-ROM into the CD-
ROM drive of the PC.
- Enter the ACU’s IP address (Factory default IP: 192.168.0.223)
- Enter the ACU’s port number (Factory default port: 4002)
- Click Connect button
NOTE:
If the remote access PC is located in the same network group with the ACU, the ACU can be
accessed through the internal IP address. But, if the remote access PC is located at the outside of
network group, the ACU’s IP address should be changed by the IP address assigned by the network
service provider. Refer to page 108 for changing the ACU’s IP address.
Establish a data
communication
WARNING:
The data volume will grow very quickly if Network Communication is in use.
Intellian recommends to use Remote Web Access to access the ACU (refer to page 86).