Connect the BLACK WIRE to any EARTH, LIVE or NEUTRAL terminal. The black wire must only

be used for connection to an external Pilot-Wire Programmer. Connection of the black wire to any other
terminal  will  destroy  the  thermostat.  If  the  black  wire  is  not  used  for  connection  to  a  Pilot-Wire
programmer, it must be properly insulated and isolated. This appliance is Double Insulated, therefore
it must not be Earthed. The cable contains: (BROWN: Live) (GREY/BLUE: Neutral) (BLACK: the Signal Wire).

This product is safe and water resistant. Nevertheless, do not touch the radiator or

the thermostat when any part of you is wet. This product is for interior use only.

Ensure  turned  off  at  the  main  power  source, and clean with a soft, non

abrasive damp cloth.  Never allow  water  to  splash  onto  any  part  of  the  appliance.

Do not lay any material over the radiator, especially if it is damp or wet. Never place

any object against the radiator. Always ensure that the radiator is installed in an open

area to allow the warmth to be radiated and not where curtains will be drawn over it.

Although this product is designed to ensure safety and ease of use, like with any other

electrical or heating product, always exercise caution where children are concerned.

We strongly advise you not to allow children or any unsuitable person to operate the

controls or to tamper with any electrical connection.

Never pull, sit on, hang from or load the radiator with any weight. Such practice may

damage  the  radiator  or  cause  it  to  come  loose  from  the  wall  or  the  wall  fitting

attachments, which could cause serious injury. Also, to avoid such injury, check from

time to time to ensure that the radiator is securely fixed to the wall.

Never attempt to alter or modify this product, paint it, or apply stickers. This will

invalidate the warranty and may cause the product to malfunction or personal injury.

1.  INTELLI HEAT Ltd or any associated company or person cannot be held responsible for any fault, damage, or personal

injury caused if these instructions have not been fully adhered to, or where non-original materials or accessories

have been used. Non observance to these guidelines and all applicable regulations may invalidate the warranty.

2.  This radiator is filled with a special Thermodynamic Fluid.  Any repair involving opening the access to this fluid must

be carried out by an electrician approved by the manufacturer. The manufacturer must be contacted in the unlikely

event of any leakage of this fluid. Please note that all regulations for the disposal of heating fluid and electrical

appliances must be fully adhered to.

3.  If the cable or any other electrical part fails or becomes damaged, repair or replacement must be carried out  by an

electrician  approved  by  the  manufacturer,  or  by  a  suitably  qualified,  experienced    electrician  familiar  with  such

products who has the necessary instructions.

4.  This  product  must  not  be  positioned  below  an  electrical  socket  and  all  applicable  regulations  relating  to  the

installation of electrical appliances must be fully adhered to. See pages 4 & 6 for further information and guidance.

5.  During operation, it is normal for the radiator to make minor clicking sounds due to metal expansion/contraction,

and for one end fin, or one each side not to heat up, this allows the flow and expansion of the thermodynamic fluid.

Summary of Contents for CALI Avanti

Page 1: ...INSTALLATION AND INSTRUCTION MANUAL CALI Avanti Thermodynamic fluid filled electric radiator EN IST 03 F 038 01 By Intelligent Heating Solutions ...

Page 2: ...ocation THE PACKAGE INCLUDES Aluminium radiator fitted with a thermostat with electronic regulation kit made up of three mounting brackets and instruction manual CONTENTS 1 CHARACTERISTICS Page 3 2 DESCRIPTION AND TECHNICAL SPECIFICATIONS OF THE PRODUCT Page 3 3 WARNINGS Page 4 4 INSTALLATION Page 6 5 ELECTRICAL CONNECTIONS Page 7 6 REGULATION AND PROGRAMMING Page 8 7 CLEANING THE RADIATOR Page 12...

Page 3: ...hermodynamic fluid to transmit heat internally This thermodynamic fluid is made up of highly refined mineral oil with a high heat transmission coefficient characterized by high oxygenation resistance for durability and low viscosity The internal thermodynamic fluid is heated by means of an electrical resistor with class II insulation which has a control thermostat and safety ther mal fuse The cont...

Page 4: ... installed in an alcove less than 10 cm from the corners of the room beneath a power point on a shelf The radiator must be mounted on the wall using the standard mounting brackets included All work required on the appliance must be performed by a qualified professional Repairs which require opening the liquid reservoir must be made by the manufacturer its representatives or customer service This a...

Page 5: ... cause serious injury Also to avoid such injury check from time to time to ensure that the radiator is securely fixed to the wall Never attempt to alter or modify this product paint it or apply stickers This will invalidate the warranty and may cause the product to malfunction or personal injury 1 INTELLI HEAT Ltd or any associated company or person cannot be held responsible for any fault damage ...

Page 6: ...wer point or fuse spur Curtains furniture and objects which may obstruct proper heat distribution must be placed a minimum of 50 cm from the front of the radiator The radiator must be installed with a minimum distance of 120 mm between the floor and the lowest part of the radiator ...

Page 7: ...objects into or attempt to pierce the side of the radiator containing the regulation system right side If the power cord is damaged it must be replaced by a qualified electrician only 5 1 Details of bathroom installation The appliance must be installed according to current regulations and laws in the country of use The radiator is class II and has IP24 electrical protection In bathrooms it can be ...

Page 8: ...ing mode and the room temperature has not yet reached the desired tempe rature programmed by the user the LED is RED Once the room reaches the programmed temperature the LED turns GREEN 6 2 Changing the mode Press the mode key to select the desired mode ICON INDICATING THE SELECTED MODE PROGRAMMED TEMPERATURE LED The radiator has various operating modes as shown in the table on page 12 When the ra...

Page 9: ...used when programming 0 2 4 6 8 10 12 14 16 18 20 Setback Comfort THERMOMETER TEMPERATURE TIME 6 4 Setting times and weekly programming Press the stand by and mode keys at the same time and hold for three seconds A dot will blink on the screen next to the days of the week 1 7 The current day can be selected using the plus or minus key Use the mode key to confirm the selection The number correspond...

Page 10: ...select the times when the Comfort temperature is desired Pressing the key activates the segment on the screen and there fore Comfort temperature as well Pressing the key deactivates the segment and the programmed temperature will be equivalent to the Set back temperature level PROGRAMME DAY PROGRAMME HOUR PROGRAMME MIN 0 4 8 12 16 20 24 Confirm the selection using the mode key This same process mu...

Page 11: ...re control centre 6 6 3 Comfort mode This is the normal mode when the radiator is in use keeping the ambient temperature at the programmed level 1 Press the mode key until the screen displays the icon 2 Select the desired temperature using the and keys 6 6 4 Setback mode When this operating mode is selected the radiator will keep the ambient temperature at the programmed Set back temperature The d...

Page 12: ... weekly programming which sets the two temperature levels Comfort and Night time defined by the user for each time of day Pilot wire The temperature depends on the Pilot Wire control for radiators installed in France only Stand by The receiver is in stand by Comfort Comfort status and the temperature which the environment must be kept at are transmitted Setback Night time status and the temperatur...

Page 13: ...e The radiator is not large enough for the size of the room Replace the radiator with one with greater output Ineffective ambient temperature regulation Err S The temperature sensor is broken Contact technical support for repair The radiator is leaking oil Any Defect in the body or improperly closed connections Contact technical support for repair 9 ENVIRONMENT The symbol placed on the appliance a...

Page 14: ...14 ...

Page 15: ...omagnetic compatibility DIRECTIVE 2002 96 CE of 27 January 2003 on waste from electrical and electronic equipment WEEE And in accordance with the following harmonized regulations EN 60335 1 2004 04 safety of electrical equipment for domestic or similar uses General regulations EN 60335 2 30 2006 05 safety of electrical equipment for domestic or similar uses Part 2 Specific regulations for electric...

Page 16: ...ber 05950029 Unit 18 Napier Place Stephenson Way Thetford Norfolk IP24 3RL www intelligentheat co uk E tech intelligentheat co uk www intelligentheat co uk support Intelligent Heating Solutions IST 03 F 038 01 November 2012 11 2012 0ZLIBIST52 ...

Reviews: