Intelix AUDISEY Athena Installation Manual Download Page 7

Intelix 

Audisey 

Athena 

Installation Manual 

 www.intelix.com 

 

7

Connecting Audio Cabling to the Athena  

Please follow the steps below when connecting audio cabling to the Athena 
matrix.  

1)

 

Determine if the output from the source device (CD player, 
microphone, receiver, etc.) to the Athena matrix is balanced or 
unbalanced. If unsure, refer to device’s manual.  

¾

 

If the source device output is balanced, connect the device to 
the Athena matrix using a modified cable with either an XLR 
connector or a ¼” TRS (

T

ip 

R

ight 

S

leeve) connector. 

¾

 

If the source device output is unbalanced, connect the device 
to the Athena matrix using a modified cable with an RCA 
connector. 

2)

 

Once the cable and connecter style have been determined, modify the 
cable by cutting off the connector on one end.  

3)

 

Strip back the main insulation of the cable 1/8”. Take care not to 
damage the conductors inside the cable. 

4)

 

Separate the insulated conductors from the exposed outer strands. 

5)

 

Twist together the exposed strands into a single conductor. 

6)

 

Strip back the insulation of the internally insulated conductor 1/8”. 

7)

 

Twist exposed strands of each conductor into one tightly twisted 
conductor. This will be the positive conductor or the plus and 
negative phase of a balanced source. 

8)

 

Connect the twisted conductors to the Athena matrix via removable 
screw-terminal (phoenix-type) connectors.  

9)

 

Repeat the above steps for each input source required. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Recommended Audio Cable Wiring Methods

 

Connecting an Unbalanced Source to a Balanced Input 

1)

 

Cut a piece of audio cable about 1” long. 

2)

 

Pull out the conductors from the cable and twist together so that 
there is now a single 1” long conductor. 

3)

 

Bend and insert each end of 1” long conductor into terminals 
(

GND

) and (-) of the Phoenix-type plug receptacles of the 

Athena unit. 

4)

 

Insert positive twisted conductor into terminal (+) of the 
phoenix-type plug receptacle. 

5)

 

Insert ground twisted conductor into terminal (+) of the 
phoenix-type plug receptacle. 

Summary of Contents for AUDISEY Athena

Page 1: ...Audisey Athena by Intelix...

Page 2: ...tion point within an equilateral triangle symbol is intended to alert the user to the presence of important operating and maintenance servicing instructions tin the literature accompanying the product...

Page 3: ...the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moist...

Page 4: ...owering the Athena 12 Powering Down the Athena 12 Installing Athena Software 13 Controlling the Athena 14 Control via a Dedicated Computer 14 Control via RS232 14 Control via USB 15 Control via Ethern...

Page 5: ...essing and either eight or sixteen channels of independent power amplification The Athena provides users with up to 128 system presets 16 input DSP presets per channel and 16 output DSP presets per ch...

Page 6: ...of the Athena matrix for proper side ventilation Ensure there are no closeable doors on the rack that might seal the Athena matrix from a steady supply of cool air All Athena matrices are equipped wi...

Page 7: ...4 Separate the insulated conductors from the exposed outer strands 5 Twist together the exposed strands into a single conductor 6 Strip back the insulation of the internally insulated conductor 1 8 7...

Page 8: ...lanced Source to a Balanced Input 1 Insert positive twisted conductor into terminal of the Phoenix type plug receptacle 2 Insert negative twisted conductor into terminal of the Phoenix type plug recep...

Page 9: ...Connect the other end of the coaxial cable to the SPDIF In 1 or In 2 In 1 uses audio input channels 1 and 2 and In 2 uses audio input channels 5 and 6 Note The SPDIF inputs and outputs must be activat...

Page 10: ...nd Note The speaker outputs are fully protected against shorts and over current conditions A short to ground or over current condition will cause the affected output channel to shut down for five seco...

Page 11: ...cation port and the other end to either of the RS232 ports on the Athena USB The Athena features a USB port on the front panel of the matrix Using a USB cable connect one end of the cable to the USB p...

Page 12: ...illuminate and the front panel LCD will indicate the Athena system configuration 4 Using the LCD menu confirm the output channel volume controls are set at an acceptable level Powering Down the Athen...

Page 13: ...The CD should automatically start and the Athena Autorun Wizard window should initiate If this does not occur manually select your computer s CD ROM drive and open the Autorun exe 3 Select the program...

Page 14: ...he Audisey Athena matrix mixer amplifier Simply connect the computer to the Athena via an ethernet crossover cable or serial cable Control via RS232 The Athena features two RS232 serial ports on the r...

Page 15: ...t is a 10 base T port and runs the TCP IP protocol The Athena is factory configured for DHCP host address assignment by default A fixed IP address may be assigned via Athena Designer Software Control...

Page 16: ...out Function 1 Select the Mode button until Admin appears in the LCD display 2 Turn the toggle knob until Inactivity Timeout appears in the LCD display 3 Select the Select button 4 Turn the toggle kno...

Page 17: ...On or Blank Screen Off Adjusting Output Volume for a Specific Channel 1 Select the Mode button until Output Volume appears in the LCD display 2 Select the Select button 3 Turn the toggle knob to sele...

Page 18: ...r low lit image on the front panel LCD 1 Verify power to the unit page 9 2 Verify the unit is powered on page 9 3 Increase the contrast in the Administration menu page 14 4 Verify the unit is not in B...

Page 19: ...hantom Power 15 VDC Input Impedance electronically balanced 20 kOhms unbalanced 10 kOhms Input Gain Trim Range 60 dB Monitor Outputs Monitor Output Impedance electronically balanced 440 ohms unbalance...

Page 20: ...trol 5 band parametric EQ time delay compressor limiter channel output volume Tone Corner Frequency Adjustment 20 Hz to 20 kHz Tone Gain 10 to 9 55 dB Speaker Align Time Delay 0 ms to 3 98 ms Compress...

Page 21: ...Intelix products should only be provided by qualified service personnel Please contact Intelix for a list of authorized service agents Other attempts at service or repair will void the warranty Warran...

Page 22: ...ness Please contact us with your questions and comments Intelix 2222 Pleasant View Road Suite 1 Middleton WI 53562 Phone 608 831 0880 Toll Free 866 4 MATMIX Fax 608 831 1833 www intelix com intelix in...

Page 23: ...Intelix Audisey Athena Installation Manual www intelix com 23...

Reviews: