InteliClean Air 9000 Series Manual Download Page 17

 

 

 

 

The unit will not operate properly if the strainer is clogged. 
Please clean the strainer regularly.

1. Close the water shut off valve (A)
2. Flush the toilet to empty the water reservoir
3. Use a coin to remove the strainer cap 
4. Clean the screen filter with a small brush or water
5. Re-screw the water filter nut
6. Open the water shut off valve (A)

CLEANING THE NOZZLE

CLEANING THE STRAINER

SELF CLEANING NOZZLE

When the “normal shower” button on the side control button is pressed for 
3 seconds without sitting on the seat, the nozzle will extract without spraying 
and can be cleaned with a soft toothbrush. After cleaning the nozzle,
push “Stop” button on the side control panel and the nozzle retracts itself.

Before and after each use, nozzle will be automatically cleaned by fresh 
water rinsing off.

Malfunction caused by lime is not covered by the warranty.

3 seconds

CLEANING/DESCALING NOZZLE TIP AND CHANGING

With lime-containing water, limescale in the shower nozzle easily settles 
and reduces showering power. The nozzle tip can be removed / exchanged
for cleaning / descaling as follows:

Open cover and seat
Press the “normal shower” button on the side control panel for 3 sec
The nozzle extracts without spraying
Fix the shower arm with one hand, with the other hand pull the shower 
nozzle off. Please make sure that the sealing o-rings do not fall into the toilet.
Clean/descale the nozzle tip with commercially available descaling agents
For attaching the nozzle tip please use a little Vaseline
Then press the “stop button” on the side control panel

CLEANING THE BODY OF UNIT

When you clean the unit, do not use “thinner”, “benzene” or toilet bowl 
cleaner. It may cause damage to the surface of unit. Use a wet cloth. 
Do not spray water directly on to the unit. When you clean the unit, 
disconnect the power plug.

Use only liquids for cleaning the unit.

 

MAI NTENANCE

InteliClean Air Series instruction manual

-  17  -

(A)

Summary of Contents for Air 9000 Series

Page 1: ......

Page 2: ...zer installation Installation of remote control Preparation Operation Symbols of Remote Control Side Control Panel Operation of Remote Control Maintenance Troubleshooting Size information Specificatio...

Page 3: ...ain water or surface water Do not plug in the power cord before connecting the water supply hose The InteliClean Air Series digital bidet must be grounded An approved circuit breaker must be used Neve...

Page 4: ...e seat cover Do not bang the seat and lid Do not strain or push the connected hose and tube connecter it may cause water leakage Never drop or insert any object into any opening or hose If the seat is...

Page 5: ...te control 1pcs AA battery 2pcs String 1pcs Reducer 1 2 1 4 1pcs Dual check Nozzle tip Bottom Fixing Bolts 1 2 12 3 4 5 6 7 8 9 10 11 2 1 Lid 2 Control panel left 3 Deodorizer 4 Heated seat 5 LED indi...

Page 6: ...at and lid from being lowered forcefully a damping mechanism is provided to lower them gradually Do not close seat or lid roughly or too forcefully as this may damage or break the seat and or lid LED...

Page 7: ...tore the removed seat cover and screws in a safe place in case of re installation I NSTALLATI ON Caution before first installation Connect the unit only to a cold water drinking water supply Never use...

Page 8: ...well it may cause damage 4 The unit will feel a little loose on the toilet bowl Adjust the fit from front to back and side to side for balance 5 Tighten the nuts on both bolts securely InteliClean Air...

Page 9: ...2 Take the protection A away gently Be careful of not breaking hook parts 3 Cut both sides of protection A Carefully using a cutter 4 Hook the protection A back on the bottom of the unit 5 Screw to fi...

Page 10: ...you can also change the deodorant case First activating using of the unit Open the water supply Plug in Water tank will be filled up automatically please wait until beeping Simultaneously green LED o...

Page 11: ...e remote control on the bracket and gently slide it to left to fix it completely Note Failure to install the batteries properly could cause damage or failure of the remote control unit The remote cont...

Page 12: ...tended wash allow about one minute for water to reheat Stop Nozzle position Water pressure adjustment Seat temperature Water temperature Cleansing normal shower Cleansing lady shower Cleansing intensi...

Page 13: ...function will not work during the intensive shower Press the same shower button again to stop the oscillation shower Cleansing intensive shower Press intensive shower Automatically the water nozzle c...

Page 14: ...d mode is activated Warm air dryer Press this button and dry air is gently directed to washed area for 3 minutes Warm air temperature can be adjusted by pressing or button Can be adjusted to 5 separat...

Page 15: ...l Press this button again to release this function During Child function activating intensive shower will not work Child mode will be released automatically in 15 minutes Note After sitting down on th...

Page 16: ...t work until it is activated by users Economy 1 holiday energy saving Off This energy saving mode turns the power off Power off Press Stop button on the side control for 3 seconds The unit will memori...

Page 17: ...nty 3 seconds CLEANING DESCALING NOZZLE TIP AND CHANGING With lime containing water limescale in the shower nozzle easily settles and reduces showering power The nozzle tip can be removed exchanged fo...

Page 18: ...mpletely drained To re supply water after draining open the water shut off valve Note Do not turn upside down Do not drink the drained water Push the button on the right side of the unit to release th...

Page 19: ...he stop button till it beep Replace the batteries Water is leaking after self cleaning of the nozzle Check the water supply system If water is leaking from the main unit call the place you purchased t...

Page 20: ...idet seat 9000E Elongated Remote control for InteliClean Air Series digital bidet seat 9000 SI ZE I NFORMATI ON 500mm 281mm 562mm 40mm 165mm 165mm 51mm 400mm 526mm 400mm 210mm 302mm 56mm 27 6mm 230mm...

Page 21: ...irect connection to the water supply tubes 1 water supply pipe 740mm length Dimension M10 M 1 t valve 3 8 inside and 2x outside spare nut 1 1 2 F to 3 8 M spare nut 2 1 2 M to 3 8 F 0 5 1 0 Litre min...

Page 22: ...inteliclean com au www inteliclean com au InteliClean Air Series 9000 inteliclean com au...

Page 23: ......

Page 24: ......

Reviews: