Intelbras IVP 4101 PET User Manual Download Page 12

12

7. Test

Once installed and energized, walk in the area to be protected simulating a possible intrusion. Observe if the sensor is 
able to detect your movements during the journey, by lighting the lens. Adjust its sensitivity if necessary or reposition the 
sensor installation.

If the alarm control panel used is Intelbras, put it in test mode, this way it will not be necessary to observe the LED, as the 
control panel will indicate the sensor’s operation through siren beeps.

8. Configuring the IVP 4101 PET smart sensor (for board ver-
sion 4410350/4 and firmware 2.2.1 o earlier)

8.1.  Sensitivity adjustment of the smart IVP 4101 PET sensor

The SENS jumper (JP1) is used to control the detection sensitivity. With jumper JP1 open the sensor provides maximum 
sensitivity. With jumper JP1 closed the sensor provides minimum sensitivity. Factory default: closed.

8.2.  Setting the operating mode of the smart IVP 4101 PET sensor

Via the ECO/CONT jumper (JP2), select between intelligent continuous mode and economy mode. Factory default economy 
mode.
With jumper JP2 closed, the sensor will operate in economy mode, working as follows: After power supply, the sensor 
will work continuously for 30 minutes so that the installer can make all the adjustments to the sensor. After this time the 
sensor enters economy mode.

Eco-mode operation

The sensor will detect and transmit 1 (once) to the control panel, after this trigger, the sensor enters economic mode (low 
consumption mode without detection). In this mode, the sensor will again detect and transmit to the alarm center only 
after 2 (two) minutes of no movement in the environment. After 2 (two) minutes, the sensor will be able to detect and 
transmit the event to the central alarm. For a better understanding of Economy mode, see the timeline below.

Summary of Contents for IVP 4101 PET

Page 1: ...User manual IVP 4101 PET smart...

Page 2: ...e sensor has an integrated Temperature Sensor to offer the same detection sensitivity in different environments from 10 C to 50 C reducing the risk of false triggers DIGITAL technology SMD mounting In...

Page 3: ...reens or any object that blocks the scan Wireless communication technology when exposed to environments with high power radiation can suffer interference and have its performance impaired Example loca...

Page 4: ...done according to item 5 Configuring the sensor IVP 4101 PET smart for cards in version 4410350 5 and firmware 3 0 0 and item 8 Configuring the sensor IVP 4101 PET smart for cards version 4410350 4 a...

Page 5: ...nsor 9 5 2 Setting the operating mode of the smart IVP 4101 PET sensor 9 5 3 IVP 4101 PET smart sensor supervision adjustment 10 6 Low battery sensor 11 7 Test 12 8 Configuring the IVP 4101 PET smart...

Page 6: ...OK Anti jamming Immunity against interference from malicious signals 2 Characteristics Digital micro processed detection technology 2 levels of sensitivity 2 modes of operation CONT Continuous Intelli...

Page 7: ...d Pet Installation height h Less than or equal to 4 m Without the presence of a pet 1 8 to 2 m With the presence of a pet Greater than 4 m up to 12 m With the presence of a pet 2 1 to 2 2 m Without t...

Page 8: ...Oblongo Step 3 if the installation is done in the corner of the wall Use the holes indicated on the back cover Fixing location of the screws for installation in the wall corner Important the IVP 4101...

Page 9: ...is monitoring the environment until detecting 3 more events Note this mode of operation causes a greater consumption of battery power especially where there is a large number of people Trial period 15...

Page 10: ...tect and generate triggers in the central starting the cycle again Per odo de teste 15 min Per odo de estabiliza o Tempo em que o sensor permanece ligado Modo Cont nuo inteligente 2 min Ap s colocar a...

Page 11: ...ired adjustments follow the steps below Open the IVP 4001 PET smart Set the jumpers to the desired settings Take a trigger to effect changes to the sensor configuration Note do not register the sensor...

Page 12: ...d the sensor provides minimum sensitivity Factory default closed 8 2 Setting the operating mode of the smart IVP 4101 PET sensor Via the ECO CONT jumper JP2 select between intelligent continuous mode...

Page 13: ...3 consecutive shots within an interval of 135 seconds if there are movements Right after the 3 shots or an interval of 135 seconds the sensor will enter the SLEEP period that is it needs to stay again...

Page 14: ...ed to protection against harmful interference even from stations of the same type and may not cause interference to systems operating on a primary basis This is a product approved by Anatel the approv...

Page 15: ...arties foreign to the manufacturer b if the damage to the product arises from accidents disasters agents of nature lightning floods landslides etc humidity voltage in the electrical network excess vol...

Page 16: ...Support via e mail suporte intelbras com br Customer Service 0800 7042767 Where to buy Who installs it 0800 7245115 Produced by Intelbras S A Ind stria de Telecomunica o Eletr nica Brasileira Rodovia...