6
1. Technical specifications
Supply voltage
12 ~ 24 Vdc
Consumption current
≤50 mA @ 12 Vdc
Range
Internal
30 m
External
15 m
Alarm output
Configurable output
NO/NC
1 A @ 24 Vdc
1 A @ 127 Vac
Relay opening time
1s or 2,5s ± 10%
Response time
50ms
Indication of Alignment
Alignment LED (green)
Trigger indication
Trigger LED (red)
Outdoor sunscreen
Yes
Operating Temperature
-10 ºC to + 55 ºC
IP protection
IP55
Color
Black
Dimensions (W × H × D)
50 × 29 × 75,35 mm
2. Product
1
5
5
5
5
5
6
3
10
10
4
9
2
6
7
8
1. Transmitter
2. Receiver
3. Front cover
4. Sealing rubber
5. Screw hole for fixing
6. Cable routing
7. Lens
8. TX terminal block
9. RX terminal blocks
10. Screw hole for fixing the front cover
Summary of Contents for IVA 3015X
Page 1: ...User s Manual IVA 3015 X...