3. Secure the sensors in the installation position following the recommendations below:
» Do not install the sensor upside down.
» Orient yourself by the positioning arrows located on the articulated sensor support.
Down
Down
Down
Down
4. Turn on the power on the receiver and transmitter board (10 ~ 24 Vdc / Vac - no polarity). After that, connect the wires
from the alarm output to the zone input of your alarm panel:
FONTE
+
12
V
GND
CM
NF
NA
10
~
24
10
~
24
Conectar
à
Central
de
Alarmes
RECEPTOR
TRANSMISSOR
Transmitter
Receiver
Connect the
alarm control panel
5. Configure the frequency channel using the
FREQ jumper. For the sensor to function correctly, the transmitter (TX) and receiver
(
RX) must be on the same frequency channel:
Frequency channels
3
FREQ
2
1
Freq.
Position 1 - Frequency channel 1 (factory default)
Position 2 - Frequency Channel 2
Position 3 - Frequency Channel 3