background image

User manual

IVA 5040 AT
IVA 5080 AT

Summary of Contents for iIVA 5040 AT

Page 1: ...User manual IVA 5040 AT IVA 5080 AT...

Page 2: ...were developed with the objective of offering an effective infrared barrier combined with a high flexibility of installation and alignment through its articulation system Both models have more configu...

Page 3: ...commended distance Always check that there are no reflections on clear and polished surfaces which can prevent the sensor from triggering Do walking tests in different positions along the barrier to m...

Page 4: ...TX CHANNEL 2 TX CHANNEL 2 P e r i m e t e r RX CHANNEL 1 RX CHANNEL 2 TX CHANNEL 3 RX CHANNEL 3 RX CHANNEL 2 In order to avoid interference between sensors that may be on the same channel respect the...

Page 5: ...m 80 m 120m1 Side Protection Distance DPL 3 m 5 m 7 m Vertical Protection Distance DPV Maximum stacking of 3 sensors 1 Distance to indoor area only That is for both IVA 5040 AT and IVA 5080 AT the si...

Page 6: ...Summary 1 Technical specifications 7 2 Product 8 3 Installation 9 4 Troubleshooting 13 Warranty term 14...

Page 7: ...40 m 80 m Indoor 60 m 120 m Alarm output NA and NF output 2 A 24 Vdc Alarm Time 2s Response time 50 ms to 1s adjustable by trimpot Detection method Block 1 beam Block 2 simultaneous beams Alignment in...

Page 8: ...do Tempo de Resposta LEDS Alinhamento e Disparo RX TX RX TX RX Suporte Articul vel Gabinete Principal Tampa Frontal 360 180 360 180 IVA 5080 AT IVA 5040 AT Main Cabinet Front cover Articulating suppor...

Page 9: ...uso Remova a tampa frontal conforme movimento indicado na figura utilize abertura localizada na parte inferior da tampa frontal para facilitar a remo o Remove the screw TX and RX identification IVA 50...

Page 10: ...connect the wires from the alarm output to the zone input of your alarm panel FONTE 12V GND CM NF NA 10 24 10 24 Conectar Central de Alarmes RECEPTOR TRANSMISSOR Transmitter Receiver Connect the alar...

Page 11: ...ry alignment which will avoid false or unwanted triggering the alignment must be optimal only green LED on Green LED RX Alignment quality Alarm output Red LED Probability of false alarm Turned Off Bea...

Page 12: ...tment attaching screw Locking screw 9 To close the sensor follow the steps below 1 Place the sealing rubber in the passage of the wires in the TX and RX Fig 1 2 Place the front cover attach the upper...

Page 13: ...the installation wiring and that the supply voltage in the TX and RX is between 10 and 24 Vdc Vac 3 Check that both TX and RX are on the same frequency channel which is selected via the FREQ jumper 4...

Page 14: ...y the Consumer or by third parties foreign to the manufacturer b if the damage to the product arises from accidents disasters agents of nature lightning floods landslides etc humidity voltage in the e...

Page 15: ...te tecnico Support via e mail suporte intelbras com br Customer Service 0800 7042767 Where to buy Who installs it 0800 7245115 Imported to Brazil by Intelbras S A Ind stria de Telecomunica o Eletr nic...