Environmental Limits
Intel® Storage Server SSR212MC2
34 Revision
1.2
8. Environmental
Limits
8.1 System Office Environment
Table 20: System Office Environment Summary
Parameter
Limits
Operating Temperature
10
degrees celcius to +35
degrees celcius with the maximum rate of
change not to exceed 10 degrees celcius per hour.
Non-Operating Temperature -40
degrees celcius to +70
degrees celcius
Non-Operating Humidity
95%, non-condensing at 35 degrees celcius
Acoustic noise
7.0 BA (Rackmount) in an active state at typical office ambient
temperature. (23 ± degrees celcius)
Operating Shock
No errors with a half sine wave shock of 2 G (with 11 millisecond
duration)
Package Shock
Operational after a 24 inch free fall, although cosmetic damage may be
present (chassis weight 30 lbs)
Electrostatic Discharge (ESD) ±15 Kilovolt (KV) per Intel
®
Environmental test specification
System Cooling Requirement
in British Thermal Units (BTU)
per Hour
3600 BTU/hour (at 850W)
8.2 System Environmental Testing
The system has been tested per the
Intel
®
Environmental Standards Handbook
, Intel document
number 662394-03. These tests include:
•
Temperature Operating and Non-Operating
•
Humidity Non-Operating
•
Packaged and Unpackaged Shock
•
Packaged and Unpackaged Vibration
•
AC Voltage, Frequency and Source Interrupt
•
AC Surge
•
Acoustics
•
ESD
•
EMC Radiated Investigation