Disk on Module (DOM) Install Guide:  Intel® Storage System SSR212MA

Warnings

Heed safety instructions:

 Before working with your server product, whether you are 

using this guide or any other resource as a reference, pay close attention to the safety 

instructions. You must adhere to the assembly instructions in this guide to ensure and 

maintain compliance with existing product certifications and approvals.  Use only the 

described, regulated components specified in this guide.  Use of other products / 

components will void the UL listing and other regulatory approvals of the product and 

will most likely result in noncompliance with product regulations in the region(s) in which 

the product is sold.

System power on/off:

 The power button DOES NOT turn off the system AC power.  To 

remove power from system, you must unplug the AC power cord from the wall outlet.  

Make sure the AC power cord is unplugged before you open the chassis, add, or remove 

any components.

Hazardous conditions, devices and cables:

 Hazardous electrical conditions may be 

present on power, telephone, and communication cables.  Turn off the server and 

disconnect the power cord, telecommunications systems, networks, and modems attached 

to the server before opening it.  Otherwise, personal injury or equipment damage can 

result.

Electrostatic discharge (ESD) and ESD protection:

 ESD can damage disk drives, 

boards, and other parts.  We recommend that you perform all procedures in this chapter 

only at an ESD workstation.  If one is not available, provide some ESD protection by 

wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on 

your server when handling parts.

ESD and handling boards:

 Always handle boards carefully.  They can be extremely 

sensitive to ESD.  Hold boards only by their edges.  After removing a board from its 

protective wrapper or from the server, place the board component side up on a grounded, 

static free surface.  Use a conductive foam pad if available but not the board wrapper.  Do 

not slide board over any surface.

Installing or removing jumpers:

 A jumper is a small plastic encased conductor that slips 

over two jumper pins.  Some jumpers have a small tab on top that you can grip with your 

fingertips or with a pair of fine needle nosed pliers.  If your jumpers do not have such a 

tab, take care when using needle nosed pliers to remove or install a jumper; grip the 

narrow sides of the jumper with the pliers, never the wide sides.  Gripping the wide sides 

can damage the contacts inside the jumper, causing intermittent problems with the 

function controlled by that jumper.  Take care to grip with, but not squeeze, the pliers or 

other tool you use to remove a jumper, or you may bend or break the pins on the board.

Summary of Contents for SSR212MA

Page 1: ...Disk on Module DOM Install Guide Intel Storage System SSR212MA A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies Products Intel Order Number D23738 001 ...

Page 2: ...ccur Intel may make changes to specifications and product descriptions at any time without notice Intel server boards contain a number of high density VLSI and power delivery components that need adequate airflow for cooling Intel s own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together It is the responsib...

Page 3: ...otherboards server sb cs 010770 htm Consignes de sécurité Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction Consultez Intel Server Boards and Server Chassis Safety Information sur le Intel Server Deployment Toolkit CD ou bien rendez vous sur le site http support intel com support motherboards server sb cs 010770 htm ...

Page 4: ...quipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage disk drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts ESD and h...

Page 5: ...écurité iii Instrucciones de seguridad importantes iii Warnings iv Disk on Module DOM Install Guide 1 Tools Needed 1 Kit Contents 1 DOM Installation Instructions 1 Prepare System 1 Remove Enclosure Cover 2 Remove Processor Air Duct 4 Remove PCI Riser Assembly 5 Install Replacement DOM 6 Install PCI Riser Assembly 9 Install Processor Air Duct 10 Close Enclosure Cover 11 Complete Setup 11 ...

Page 6: ...Contents vi Disk on Module DOM Install Guide Intel Storage System SSR212MA ...

Page 7: ...igure 3 Removing Processor Air Duct 4 Figure 4 Removing PCI Riser Assembly from Chassis 5 Figure 5 Disconnecting Power Cable from DOM 6 Figure 6 Removing Old DOM 7 Figure 7 Installing Replacement DOM 7 Figure 8 Connecting Power Cable to DOM 8 Figure 9 Installing PCI Riser Assembly into Chassis 9 Figure 10 Installing Processor Air Duct 10 Figure 11 Closing Enclosure Cover 11 ...

Page 8: ...List of Figures viii Disk on Module DOM Install Guide Intel Storage System SSR212MA ...

Page 9: ...ment before performing any of the steps See the Intel Server Boards and Server Chassis Safety Information document at http support intel com support motherboards server sb cs 010770 htm for a complete listing of all caution and safety statements Caution Before performing any maintenance on the system back up the data Follow the instructions in the Intel Storage System Software User Manual for shut...

Page 10: ...r 5 Release the lock by turning the screw see letter A in the following figure a quarter turn until the unlock symbol aligns with the notch on the cover Press in on the palm latch see letter B and slide the enclosure cover back see letter C until it stops about 2 inches Figure 1 Unlatching Enclosure Cover TP01851 C B A ...

Page 11: ...A 3 6 Next slide the enclosure cover forward see letter A in the following figure up to the blue lid removal zone displayed on the top of the cooling module see letter B Lift the enclosure cover see letter C to completely remove it from the chassis Figure 2 Removing Enclosure Cover TP01827 A C B ...

Page 12: ...stall Guide 4 Disk on Module DOM Install Guide Intel Storage System SSR212MA Remove Processor Air Duct 7 Lift the processor air duct from its location over the processor socket s Figure 3 Removing Processor Air Duct TP01856 ...

Page 13: ...e PCI riser assembly and lift the assembly out of the chassis see letter B Lay the PCI riser assembly over on its side see letter C Be sure to support the PCI riser assembly so that the connectors on the PCI riser assembly and components on the PCI RAID controller card s are not rubbing against the sheet metal of the chassis Figure 4 Removing PCI Riser Assembly from Chassis TP00879 B A A C ...

Page 14: ...ide 6 Disk on Module DOM Install Guide Intel Storage System SSR212MA Install Replacement DOM 9 Disconnect the power cable from the old DOM see letter A in the following figure Figure 5 Disconnecting Power Cable from DOM TP01863 A A ...

Page 15: ...old DOM by pressing in on the latches on both sides of the DOM see letter A in the following figure and pull up to remove the DOM Figure 6 Removing Old DOM 11 Install the replacement DOM to the server board s IDE connector You should feel it snap into place Figure 7 Installing Replacement DOM TP01864 A A TP01865 ...

Page 16: ...Disk on Module DOM Install Guide 8 Disk on Module DOM Install Guide Intel Storage System SSR212MA 12 Connect the power cable to the replacement DOM Figure 8 Connecting Power Cable to DOM TP01866 ...

Page 17: ... back of the PCI riser assembly with the notches on the cross bar and rear of the chassis Guide the PCI riser assembly home by firmly gripping and sliding the assembly downwards until the riser card mates with the connector on the server board The latches should lock into position once the PCI riser assembly is seated properly Figure 9 Installing PCI Riser Assembly into Chassis TP00876 ...

Page 18: ...all Guide 10 Disk on Module DOM Install Guide Intel Storage System SSR212MA Install Processor Air Duct 14 Reinstall the processor air duct over the processor on the server board Figure 10 Installing Processor Air Duct TP01855 ...

Page 19: ...front of the chassis see letter B With a screwdriver secure the enclosure cover to the chassis by turning the lock see letter C a quarter turn until the lock symbol aligns with the notch on the cover Figure 11 Closing Enclosure Cover Complete Setup 16 Re connect all peripheral devices and the AC power cable Power up the storage system 17 Refer to the Intel Storage System Software User Manual for i...

Page 20: ...Disk on Module DOM Install Guide 12 Disk on Module DOM Install Guide Intel Storage System SSR212MA ...