Technical Specifications
24
3.3.2
Electrical Characteristics
Table 3-3 lists the maximum power requirements for the RAID Controller SRCS16 under
normal operation.
3.3.3
Thermal and Atmospheric Characteristics
The atmospheric characteristics for the RAID Controller SRCS16 are:
•
Temperature range: 0 °C to 45 °C (dry bulb)
•
Relative humidity range: 20% to 80% noncondensing
•
Maximum dew point temperature: 32 °C
The following parameters define the storage and transit environment for the RAID Controller
SRCS16:
•
Temperature range: 40 °C to 105 °C (dry bulb)
•
Relative humidity range: 20% to 80% noncondensing
3.3.4
Safety Characteristics
The RAID Controller SRCS16 meets or exceeds the requirements of UL flammability rating
94 V0. Each board is marked with the supplier’s name or trademark, type, and UL
flammability rating. Because these boards are installed in a PCI bus slot, all voltages are
below the SELV 42.4 V limit.
Table 3-3 RAID Controller SRCS16 Maximum Power Requirements
RAID Controller
PCI/PCI-X +5.0 V PCI/PCI-X +3.3 V Power
Over the Operating
Range
SRCS16
1
(load sharing enabled)
1. The total power for the SRCS16 has taken into consideration the charging of the BBU from the +12
V and the on-board regulator efficiencies.
0.85 A
1.29 A
11 W
0 °C to 45 °C
SRCS16
1
(load sharing disabled)
1.63 A
0 A